2005European Journal of OphthalmologyRequires access

Retinal Nerve Fiber Layer Measured by Heidelberg Retina Tomograph and Nerve Fiber Analyzer

Michele Iester, A. Mermoud

Open publisher page 7 citations

Abstract

PURPOSE: To compare retinal nerve fiber layer (RNFL) thickness measured by Heidelberg retina tomograph (HRT) and nerve fiber analyzer (GDx). METHODS: Twenty eyes of 20 consecutive healthy subjects were recruited for this study. Each subject had a normal visual field and a normal optic nerve head, which was assessed by slit-lamp biomicroscopy using a 90 degrees lens. Using the HRT and GDx, RNFL measurement was calculated as for software vs 2.01 and vs 1.0.14, respectively. Retinal nerve fiber layer thickness was evaluated for the entire annulus surface every 5 degrees degrees. RNFL was assessed by HRT and GDx. HRT RNFL measurement was calculated at 0 microm from the edge, while GDx RNFL measurement at 1.75 disc diameter as for software. The difference between the highest points and the deepest points was calculated and compared. Furthermore, because of the possibility of different scales in the two systems, the following ratio was calculated: superior/inferior, superior/temporal, superior/nasal, inferior/temporal, and inferior/nasal. RESULTS: When the entire RNFL thickness was considered, a significant (p<0.001) difference was found between the HRT and GDx measurements. A difference of 200 microm was found between the highest and the deepest HRT points while a difference of 40 microm was found between the highest and the deepest GDx points. CONCLUSIONS: HRT and GDx RNFL measurements were statistically different in each sector. However, ratio parameters showed no difference between the obtained values except for superior/temporal ratio and inferior/temporal ratio.

About this research paper

What this paper is about

PURPOSE: To compare retinal nerve fiber layer (RNFL) thickness measured by Heidelberg retina tomograph (HRT) and nerve fiber analyzer (GDx). METHODS: Twenty eyes of 20 consecutive healthy subjects were recruited for this study. Each subject had a normal visual field and a normal optic nerve head, which was assessed by slit-lamp biomicroscopy using a 90 degrees lens. Using the HRT and GDx, RNFL measurement was calculated as for software vs 2.01 and vs 1.0.14, respectively. Retinal nerve fiber layer thickness was evaluated for the entire annulus surface every 5 degrees degrees. RNFL was assessed by HRT and GDx. HRT RNFL measurement was calculated at 0 microm from the edge, while GDx RNFL measurement at 1.75 disc diameter as for software. The difference between the highest points and the deepest points was calculated and compared. Furthermore, because of the possibility of different scales in the two systems, the following ratio was calculated: superior/inferior, superior/temporal, superior/nasal, inferior/temporal, and inferior/nasal. RESULTS: When the entire RNFL thickness was considered, a significant (p<0.001) difference was found between the HRT and GDx measurements. A difference of 200 microm was found between the highest and the deepest HRT points while a difference of 40 microm was found between the highest and the deepest GDx points. CONCLUSIONS: HRT and GDx RNFL measurements were statistically different in each sector. However, ratio parameters showed no difference between the obtained values except for superior/temporal ratio and inferior/temporal ratio.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To compare retinal nerve fiber layer (RNFL) thickness measured by Heidelberg retina tomograph (HRT) and nerve fiber analyzer (GDx). METHODS: Twenty eyes of 20 consecutive healthy subjects were recruited for this study. Each subject had a normal visual field and a normal optic nerve head, which was assessed by slit-lamp biomicroscopy using a 90 degrees lens. Using the HRT and GDx, RNFL measurement was calculated as for software vs 2.01 and vs 1.0.14, respectively. Retinal nerve fiber layer thickness was evaluated for the entire annulus surface every 5 degrees degrees. RNFL was assessed by HRT and GDx. HRT RNFL measurement was calculated at 0 microm from the edge, while GDx RNFL measurement at 1.75 disc diameter as for software. The difference between the highest points and the deepest points was calculated and compared. Furthermore, because of the possibility of different scales in the two systems, the following ratio was calculated: superior/inferior, superior/temporal, superior/nasal, inferior/temporal, and inferior/nasal. RESULTS: When the entire RNFL thickness was considered, a significant (p<0.001) difference was found between the HRT and GDx measurements. A difference of 200 microm was found between the highest and the deepest HRT points while a difference of 40 microm was found between the highest and the deepest GDx points. CONCLUSIONS: HRT and GDx RNFL measurements were statistically different in each sector. However, ratio parameters showed no difference between the obtained values except for superior/temporal ratio and inferior/temporal ratio.

Key concepts: Nerve fiber layer, Retinal, Ophthalmology, Nerve fiber, Medicine, Retina, Anatomy, Glaucoma

Related papers

Back to paper searchBrowse research topicsOriginal source
Retinal Nerve Fiber Layer Measured by Heidelberg Retina Tomograph and Nerve Fiber Analyzer — Research Paper | ScholarLens