2024•SustainabilityOpen access

The Analysis and Validation of the Measured Heating Energy Consumption of a Single-Family Residential Passive House in Lithuania

R.A. Adomaitis, Kęstutis Valančius, Giedrė Streckienė

Open full text 1 citations

Abstract

To build a sustainable building, we need to assess a range of sustainability aspects and design them correctly, which is why building performance simulation (BPS) at an early stage of project development is critical and relevant for many professionals. This paper presents an extended analysis of the monitoring results of the first single-family Passive House (LT-PH3) in Vilnius, Lithuania, certified by the German Passive House Institute in 2015 for 2016–2020. It was based on measured data on heat pump electricity consumption and outdoor and indoor air temperature. This study evaluated the seasonal performance (SCOP) of the heat pump using the Passive House Design Package 8.5 (PHPP 8.5) and Aquarea Designer Online Simulation Software Tool 2013 (Aquarea 2013) and compared the performance of the building with the PHPP 8.5 designed in 2013 and Swegon ESBO Light 2.4.0.3 (Swegon 2.4.0.3), Aquarea 2013, and the results obtained using the Lithuanian National Building Energy Performance Certification Programme NRGsert edition 3 (NRGsert 3). The analysis showed that the heat consumption of the building modelled during the design process is close to the operational heat consumption, which increases the confidence in the BPS modelling software, the modelling process itself, and the results.

Open-access reader

About this research paper

What this paper is about

To build a sustainable building, we need to assess a range of sustainability aspects and design them correctly, which is why building performance simulation (BPS) at an early stage of project development is critical and relevant for many professionals. This paper presents an extended analysis of the monitoring results of the first single-family Passive House (LT-PH3) in Vilnius, Lithuania, certified by the German Passive House Institute in 2015 for 2016–2020. It was based on measured data on heat pump electricity consumption and outdoor and indoor air temperature. This study evaluated the seasonal performance (SCOP) of the heat pump using the Passive House Design Package 8.5 (PHPP 8.5) and Aquarea Designer Online Simulation Software Tool 2013 (Aquarea 2013) and compared the performance of the building with the PHPP 8.5 designed in 2013 and Swegon ESBO Light 2.4.0.3 (Swegon 2.4.0.3), Aquarea 2013, and the results obtained using the Lithuanian National Building Energy Performance Certification Programme NRGsert edition 3 (NRGsert 3). The analysis showed that the heat consumption of the building modelled during the design process is close to the operational heat consumption, which increases the confidence in the BPS modelling software, the modelling process itself, and the results.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To build a sustainable building, we need to assess a range of sustainability aspects and design them correctly, which is why building performance simulation (BPS) at an early stage of project development is critical and relevant for many professionals. This paper presents an extended analysis of the monitoring results of the first single-family Passive House (LT-PH3) in Vilnius, Lithuania, certified by the German Passive House Institute in 2015 for 2016–2020. It was based on measured data on heat pump electricity consumption and outdoor and indoor air temperature. This study evaluated the seasonal performance (SCOP) of the heat pump using the Passive House Design Package 8.5 (PHPP 8.5) and Aquarea Designer Online Simulation Software Tool 2013 (Aquarea 2013) and compared the performance of the building with the PHPP 8.5 designed in 2013 and Swegon ESBO Light 2.4.0.3 (Swegon 2.4.0.3), Aquarea 2013, and the results obtained using the Lithuanian National Building Energy Performance Certification Programme NRGsert edition 3 (NRGsert 3). The analysis showed that the heat consumption of the building modelled during the design process is close to the operational heat consumption, which increases the confidence in the BPS modelling software, the modelling process itself, and the results.

Key concepts: Single-family detached home, Passive house, Single family, Energy consumption, Consumption (sociology), Agricultural economics, Environmental economics, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
The Analysis and Validation of the Measured Heating Energy Consumption of a Single-Family Residential Passive House in Lithuania — Research Paper | ScholarLens