2024Unpublished venueRequires access

Morphology of Anterolateral Ligament: A Cadaveric Study and Its Implications for Knee Reconstructive Surgery

Anita Rahul Gune, Aryan Rahul Gune

Open publisher page 0 citations

Abstract

Background: The anterolateral ligament (ALL) arises from the lateral epicondyle of the femur and attaches to the tibia between Gerdy's tubercle (GT) and the fibula head. The ALL is a ligamentous tissue that gets taut when the tibia rotates 30 degrees medially. It has been suggested that the ALL of the knee plays an important role in reducing rotational instability and that reconstruction of the ALL, together with the anterior cruciate ligament (ACL), may avoid a persistent pivot shift after surgery. Aims: The primary goal of the study was to identify the structure that appeared to be controlling anterolateral rotation, characterise its dimensions and attachments, and interpret them in the context of previous work. Study Design: This is a Cadaveric dissection study. Place and Duration of Study: From 2016 to 2018, this study was carried out at the Department of Anatomy, D.Y. Patil Medical College in Kolhapur. The ALL was found in 14 female and 16 male cadavers, with a total of 60 knee joints. Methodology: The ALL tissue was discovered by rotating the tibia inside. A digital caliper was used to take measurements, and the origin and insertion points were recorded. The ALL was detected with mean dimensions of 38.06 ± 3 mm on right side and 37.94 ± 3 mm on the left side, width 4.38 ± 0.25 mm on right side and 4.37 ± 0.25 mm on left side, and thickness 0.9 ± 0.02 mm on both sides. The femoral origin is Posterior and Proximal (PP) in 23, Anterior and Distal (AD) in 29, and Femoral Lateral Epicondyle in eight knee joints. The tibial insertion measured 1.79 ± 0.3 mm on the right side and 1.82 ± 0.3 mm on the left side from Gerdy's tubercle (GT), and 1.28 ± 0.03 mm from the fibula head (FH). Results: The ALL was identified in 14 females and 16 males cadavers, total 60 knee joints. This study's findings are consistent with previous research indicating that ALL is a capsular thickening with meniscus attachment. Conclusion: The data will assist surgeons in performing reconstructive surgery and selecting the most appropriate graft. Furthermore, this ligament should be included in all gross anatomy textbooks so that medical undergraduates are aware of ALL.

About this research paper

What this paper is about

Background: The anterolateral ligament (ALL) arises from the lateral epicondyle of the femur and attaches to the tibia between Gerdy's tubercle (GT) and the fibula head. The ALL is a ligamentous tissue that gets taut when the tibia rotates 30 degrees medially. It has been suggested that the ALL of the knee plays an important role in reducing rotational instability and that reconstruction of the ALL, together with the anterior cruciate ligament (ACL), may avoid a persistent pivot shift after surgery. Aims: The primary goal of the study was to identify the structure that appeared to be controlling anterolateral rotation, characterise its dimensions and attachments, and interpret them in the context of previous work. Study Design: This is a Cadaveric dissection study. Place and Duration of Study: From 2016 to 2018, this study was carried out at the Department of Anatomy, D.Y. Patil Medical College in Kolhapur. The ALL was found in 14 female and 16 male cadavers, with a total of 60 knee joints. Methodology: The ALL tissue was discovered by rotating the tibia inside. A digital caliper was used to take measurements, and the origin and insertion points were recorded. The ALL was detected with mean dimensions of 38.06 ± 3 mm on right side and 37.94 ± 3 mm on the left side, width 4.38 ± 0.25 mm on right side and 4.37 ± 0.25 mm on left side, and thickness 0.9 ± 0.02 mm on both sides. The femoral origin is Posterior and Proximal (PP) in 23, Anterior and Distal (AD) in 29, and Femoral Lateral Epicondyle in eight knee joints. The tibial insertion measured 1.79 ± 0.3 mm on the right side and 1.82 ± 0.3 mm on the left side from Gerdy's tubercle (GT), and 1.28 ± 0.03 mm from the fibula head (FH). Results: The ALL was identified in 14 females and 16 males cadavers, total 60 knee joints. This study's findings are consistent with previous research indicating that ALL is a capsular thickening with meniscus attachment. Conclusion: The data will assist surgeons in performing reconstructive surgery and selecting the most appropriate graft. Furthermore, this ligament should be included in all gross anatomy textbooks so that medical undergraduates are aware of ALL.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background: The anterolateral ligament (ALL) arises from the lateral epicondyle of the femur and attaches to the tibia between Gerdy's tubercle (GT) and the fibula head. The ALL is a ligamentous tissue that gets taut when the tibia rotates 30 degrees medially. It has been suggested that the ALL of the knee plays an important role in reducing rotational instability and that reconstruction of the ALL, together with the anterior cruciate ligament (ACL), may avoid a persistent pivot shift after surgery. Aims: The primary goal of the study was to identify the structure that appeared to be controlling anterolateral rotation, characterise its dimensions and attachments, and interpret them in the context of previous work. Study Design: This is a Cadaveric dissection study. Place and Duration of Study: From 2016 to 2018, this study was carried out at the Department of Anatomy, D.Y. Patil Medical College in Kolhapur. The ALL was found in 14 female and 16 male cadavers, with a total of 60 knee joints. Methodology: The ALL tissue was discovered by rotating the tibia inside. A digital caliper was used to take measurements, and the origin and insertion points were recorded. The ALL was detected with mean dimensions of 38.06 ± 3 mm on right side and 37.94 ± 3 mm on the left side, width 4.38 ± 0.25 mm on right side and 4.37 ± 0.25 mm on left side, and thickness 0.9 ± 0.02 mm on both sides. The femoral origin is Posterior and Proximal (PP) in 23, Anterior and Distal (AD) in 29, and Femoral Lateral Epicondyle in eight knee joints. The tibial insertion measured 1.79 ± 0.3 mm on the right side and 1.82 ± 0.3 mm on the left side from Gerdy's tubercle (GT), and 1.28 ± 0.03 mm from the fibula head (FH). Results: The ALL was identified in 14 females and 16 males cadavers, total 60 knee joints. This study's findings are consistent with previous research indicating that ALL is a capsular thickening with meniscus attachment. Conclusion: The data will assist surgeons in performing reconstructive surgery and selecting the most appropriate graft. Furthermore, this ligament should be included in all gross anatomy textbooks so that medical undergraduates are aware of ALL.

Key concepts: Cadaveric spasm, Anterolateral ligament, Medicine, Anatomy, Ligament, Reconstructive surgery, Morphology (biology), Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Morphology of Anterolateral Ligament: A Cadaveric Study and Its Implications for Knee Reconstructive Surgery — Research Paper | ScholarLens