2024Insights into ImagingOpen access

Digital breast tomosynthesis in breast cancer screening: an ethical perspective

Simon Rosenqvist, Johan Brännmark, Magnus Dustler

Open full text 2 citations

Abstract

Although digital breast tomosynthesis has higher sensitivity than digital mammography and at least as high specificity, digital mammography remains the most common method for conducting mammographic screening. At the same time, mammography systems are now delivered "DBT-ready" and can be used for either digital mammography or digital breast tomosynthesis. In this paper, we ask whether it is ethically permissible to use such equipment for digital mammography, given its lower sensitivity. We argue it is not, and that clinics are ethically required to use their DBT-ready equipment to screen with digital breast tomosynthesis whenever this is practically possible. Our argument relies on a comparison between digital breast tomosynthesis and a hypothesized improvement in the image quality of digital mammography. CRITICAL RELEVANCE STATEMENT: Women may lose out on the benefits of screening with digital breast tomosynthesis when DBT-ready equipment is used to screen with digital mammography; we argue that this practice is ethically problematic. KEY POINTS: Digital breast tomosynthesis finds more cases of breast cancer than digital mammography. Mammography equipment can often be used to screen with both digital breast tomosynthesis and digital mammography. When they can, clinics are ethically required to use existing equipment to screen with digital breast tomosynthesis instead of digital mammography.

Open-access reader

About this research paper

What this paper is about

Although digital breast tomosynthesis has higher sensitivity than digital mammography and at least as high specificity, digital mammography remains the most common method for conducting mammographic screening. At the same time, mammography systems are now delivered "DBT-ready" and can be used for either digital mammography or digital breast tomosynthesis. In this paper, we ask whether it is ethically permissible to use such equipment for digital mammography, given its lower sensitivity. We argue it is not, and that clinics are ethically required to use their DBT-ready equipment to screen with digital breast tomosynthesis whenever this is practically possible. Our argument relies on a comparison between digital breast tomosynthesis and a hypothesized improvement in the image quality of digital mammography. CRITICAL RELEVANCE STATEMENT: Women may lose out on the benefits of screening with digital breast tomosynthesis when DBT-ready equipment is used to screen with digital mammography; we argue that this practice is ethically problematic. KEY POINTS: Digital breast tomosynthesis finds more cases of breast cancer than digital mammography. Mammography equipment can often be used to screen with both digital breast tomosynthesis and digital mammography. When they can, clinics are ethically required to use existing equipment to screen with digital breast tomosynthesis instead of digital mammography.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Although digital breast tomosynthesis has higher sensitivity than digital mammography and at least as high specificity, digital mammography remains the most common method for conducting mammographic screening. At the same time, mammography systems are now delivered "DBT-ready" and can be used for either digital mammography or digital breast tomosynthesis. In this paper, we ask whether it is ethically permissible to use such equipment for digital mammography, given its lower sensitivity. We argue it is not, and that clinics are ethically required to use their DBT-ready equipment to screen with digital breast tomosynthesis whenever this is practically possible. Our argument relies on a comparison between digital breast tomosynthesis and a hypothesized improvement in the image quality of digital mammography. CRITICAL RELEVANCE STATEMENT: Women may lose out on the benefits of screening with digital breast tomosynthesis when DBT-ready equipment is used to screen with digital mammography; we argue that this practice is ethically problematic. KEY POINTS: Digital breast tomosynthesis finds more cases of breast cancer than digital mammography. Mammography equipment can often be used to screen with both digital breast tomosynthesis and digital mammography. When they can, clinics are ethically required to use existing equipment to screen with digital breast tomosynthesis instead of digital mammography.

Key concepts: Tomosynthesis, Digital mammography, Digital Breast Tomosynthesis, Mammography, Medicine, Breast cancer, Medical physics, Radiology