Novel tapered-and-flared fully covered self-expandable metal stent for distal bile duct obstruction
Makoto Kobayashi, Hiroki Kato, Shintaro Tominaga, Motoyoshi Yano
Abstract
Makoto Kobayashi, Hiroki Kato, Shintaro Tominaga, Motoyoshi Yano
Abstract
Stent migration is a major problem that can occur when using a fully covered self-expandable metal stent (FCSEMS) in malignant distal bile duct stricture. The K-papilla Stent (S and G Biotech, Yongin, Korea) ([ Fig. 1 ]) is an FCSEMS with both a tapered portion and flared portion. This stent can be adjusted to the shape of the distal bile duct to the duodenum and has a narrowed papillary portion, which can stabilize its position and prevent migration. Fig. 1 Tapered-and-flared fully covered self-expandable metal stent. The stent is fully covered and consists of three parts: a cylindrical body part, a tapered part, and a flared part on the duodenal side ([ Fig. 2 ]). There is a narrowing of the tapered part as it leads into the papillary portion so that the stent can conform to the shape of the bile duct. The thinnest portion is located at the orifice. The large flare on the duodenal side prevents stent migration into the bile duct. The tapered portion of the stent is subjected to oblique forces by the tumor; thus, the stent will move toward the hilar and be stabilized by the flare ([ Fig. 3 ]). Fig. 2 The stent can be adjusted to the shape of the distal bile duct to the duodenum. Fig. 3 The tapered portion of the stent is subjected to oblique forces by the tumor; thus, the stent will move toward the hilar and be stabilized by the flare. A 54-year-old woman was diagnosed with obstructive jaundice due to pancreatic head cancer. After percutaneous bile duct drainage was performed, a tapered-and-flared stent was placed endoscopically ([ Video 1 ]). The stent was deployed using the yellow marker as a guide and its position was confirmed by X-ray. Quality: mobile 360 480 720 Download The tapered-and-flared stent is unlikely to migrate because its position is fixed based on the shape of the bile duct. Slight misplacement can be corrected spontaneously.Video 1 Immediately after deployment, the stent position was slightly longer on the duodenal side ([ Fig. 4 ]), but 10 days later, endoscopy showed that the stent had moved toward the liver and was fixed in a stable position ([ Fig. 5 ]). After stent placement, the patient’s jaundice improved, preoperative chemotherapy was administered, and she underwent a pancreaticoduodenectomy. Fig. 4 Immediately after deployment, the stent position was slightly longer on the duodenal side. Fig. 5 Endoscopy 10 days later showed that the stent had moved toward the liver and was fixed in a stable position. Endoscopy_UCTN_Code_TTT_1AR_2AZ Endoscopy E-Videos https://eref.thieme.de/e-videos E-Videos is an open access online section of the journal Endoscopy , reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high-quality video and are published with a Creative Commons CC-BY license. Endoscopy E-Videos qualify for HINARI discounts and waivers and eligibility is automatically checked during the submission process. We grant 100% waivers to articles whose corresponding authors are based in Group A countries and 50% waivers to those who are based in Group B countries as classified by Research4Life (see: https://www.research4life.org/access/eligibility/ ). This section has its own submission website at https://mc.manuscriptcentral.com/e-videos . Publication History Article published online: 05 June 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Stent migration is a major problem that can occur when using a fully covered self-expandable metal stent (FCSEMS) in malignant distal bile duct stricture. The K-papilla Stent (S and G Biotech, Yongin, Korea) ([ Fig. 1 ]) is an FCSEMS with both a tapered portion and flared portion. This stent can be adjusted to the shape of the distal bile duct to the duodenum and has a narrowed papillary portion, which can stabilize its position and prevent migration. Fig. 1 Tapered-and-flared fully covered self-expandable metal stent. The stent is fully covered and consists of three parts: a cylindrical body part, a tapered part, and a flared part on the duodenal side ([ Fig. 2 ]). There is a narrowing of the tapered part as it leads into the papillary portion so that the stent can conform to the shape of the bile duct. The thinnest portion is located at the orifice. The large flare on the duodenal side prevents stent migration into the bile duct. The tapered portion of the stent is subjected to oblique forces by the tumor; thus, the stent will move toward the hilar and be stabilized by the flare ([ Fig. 3 ]). Fig. 2 The stent can be adjusted to the shape of the distal bile duct to the duodenum. Fig. 3 The tapered portion of the stent is subjected to oblique forces by the tumor; thus, the stent will move toward the hilar and be stabilized by the flare. A 54-year-old woman was diagnosed with obstructive jaundice due to pancreatic head cancer. After percutaneous bile duct drainage was performed, a tapered-and-flared stent was placed endoscopically ([ Video 1 ]). The stent was deployed using the yellow marker as a guide and its position was confirmed by X-ray. Quality: mobile 360 480 720 Download The tapered-and-flared stent is unlikely to migrate because its position is fixed based on the shape of the bile duct. Slight misplacement can be corrected spontaneously.Video 1 Immediately after deployment, the stent position was slightly longer on the duodenal side ([ Fig. 4 ]), but 10 days later, endoscopy showed that the stent had moved toward the liver and was fixed in a stable position ([ Fig. 5 ]). After stent placement, the patient’s jaundice improved, preoperative chemotherapy was administered, and she underwent a pancreaticoduodenectomy. Fig. 4 Immediately after deployment, the stent position was slightly longer on the duodenal side. Fig. 5 Endoscopy 10 days later showed that the stent had moved toward the liver and was fixed in a stable position. Endoscopy_UCTN_Code_TTT_1AR_2AZ Endoscopy E-Videos https://eref.thieme.de/e-videos E-Videos is an open access online section of the journal Endoscopy , reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high-quality video and are published with a Creative Commons CC-BY license. Endoscopy E-Videos qualify for HINARI discounts and waivers and eligibility is automatically checked during the submission process. We grant 100% waivers to articles whose corresponding authors are based in Group A countries and 50% waivers to those who are based in Group B countries as classified by Research4Life (see: https://www.research4life.org/access/eligibility/ ). This section has its own submission website at https://mc.manuscriptcentral.com/e-videos . Publication History Article published online: 05 June 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Key concepts: Major duodenal papilla, Stent, Medicine, Self-expandable metallic stent, Bile duct, Duodenum, Duct (anatomy), Common bile duct