2024JAC-Antimicrobial ResistanceOpen access

Comparison of carbapenem MIC for NDM-producing Enterobacterales by different AST methods

Alfred Lee, Eddie Chi‐Man Leung, Viola Chi Ying Chow

Open full text 6 citations

Abstract

Introduction: This study compared the performance of MIC test strip (ETEST), automated AST card (Vitek 2) and broth microdilution (BMD) in determining carbapenem susceptibility and MIC values of NDM-producing Enterobacterales. Methods: was confirmed by PCR. Identification of bacterial isolates was done by MALDI-TOF. Phenotypic susceptibility to three carbapenems (ertapenem, imipenem and meropenem) was tested by BMD, ETEST and Vitek 2. MIC values were interpreted in accordance with CLSI M100 (2022 edition). Using BMD as the reference standard, the essential agreement (EA), categorical agreement (CA), very major error (VME) and major error (ME) rates were evaluated. Results: . The EA of Vitek 2 was 97.9% for ertapenem, 25.5% for meropenem and 42.6% for imipenem. Using Vitek 2, there were 0% VMEs across all three carbapenems tested. The EA of ETEST was 53.2% for ertapenem, 55.3% for imipenem and 36.2% for meropenem. The rates of VMEs for ETEST were high too (ertapenem 8.5%, meropenem 36.2%, imipenem 26.1%). The MIC values obtained from Vitek 2 were consistently higher than those from BMD, while MICs from ETEST were consistently lower than those from BMD. Conclusions: The VME rate for ETEST was unacceptably high when BMD was used as the standard for comparison. Vitek 2 had acceptable EA and CA for ertapenem when BMD was used as the standard for comparison. For meropenem and imipenem, neither of the methods (ETEST, Vitek 2) showed acceptable EA and CA when compared with BMD.

About this research paper

What this paper is about

Introduction: This study compared the performance of MIC test strip (ETEST), automated AST card (Vitek 2) and broth microdilution (BMD) in determining carbapenem susceptibility and MIC values of NDM-producing Enterobacterales. Methods: was confirmed by PCR. Identification of bacterial isolates was done by MALDI-TOF. Phenotypic susceptibility to three carbapenems (ertapenem, imipenem and meropenem) was tested by BMD, ETEST and Vitek 2. MIC values were interpreted in accordance with CLSI M100 (2022 edition). Using BMD as the reference standard, the essential agreement (EA), categorical agreement (CA), very major error (VME) and major error (ME) rates were evaluated. Results: . The EA of Vitek 2 was 97.9% for ertapenem, 25.5% for meropenem and 42.6% for imipenem. Using Vitek 2, there were 0% VMEs across all three carbapenems tested. The EA of ETEST was 53.2% for ertapenem, 55.3% for imipenem and 36.2% for meropenem. The rates of VMEs for ETEST were high too (ertapenem 8.5%, meropenem 36.2%, imipenem 26.1%). The MIC values obtained from Vitek 2 were consistently higher than those from BMD, while MICs from ETEST were consistently lower than those from BMD. Conclusions: The VME rate for ETEST was unacceptably high when BMD was used as the standard for comparison. Vitek 2 had acceptable EA and CA for ertapenem when BMD was used as the standard for comparison. For meropenem and imipenem, neither of the methods (ETEST, Vitek 2) showed acceptable EA and CA when compared with BMD.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Introduction: This study compared the performance of MIC test strip (ETEST), automated AST card (Vitek 2) and broth microdilution (BMD) in determining carbapenem susceptibility and MIC values of NDM-producing Enterobacterales. Methods: was confirmed by PCR. Identification of bacterial isolates was done by MALDI-TOF. Phenotypic susceptibility to three carbapenems (ertapenem, imipenem and meropenem) was tested by BMD, ETEST and Vitek 2. MIC values were interpreted in accordance with CLSI M100 (2022 edition). Using BMD as the reference standard, the essential agreement (EA), categorical agreement (CA), very major error (VME) and major error (ME) rates were evaluated. Results: . The EA of Vitek 2 was 97.9% for ertapenem, 25.5% for meropenem and 42.6% for imipenem. Using Vitek 2, there were 0% VMEs across all three carbapenems tested. The EA of ETEST was 53.2% for ertapenem, 55.3% for imipenem and 36.2% for meropenem. The rates of VMEs for ETEST were high too (ertapenem 8.5%, meropenem 36.2%, imipenem 26.1%). The MIC values obtained from Vitek 2 were consistently higher than those from BMD, while MICs from ETEST were consistently lower than those from BMD. Conclusions: The VME rate for ETEST was unacceptably high when BMD was used as the standard for comparison. Vitek 2 had acceptable EA and CA for ertapenem when BMD was used as the standard for comparison. For meropenem and imipenem, neither of the methods (ETEST, Vitek 2) showed acceptable EA and CA when compared with BMD.

Key concepts: Etest, Ertapenem, Meropenem, Imipenem, Broth microdilution, Carbapenem, Microbiology, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of carbapenem MIC for NDM-producing Enterobacterales by different AST methods — Research Paper | ScholarLens