Design of Bone Tissue Engineering scaffolds using Triply Periodic Minimal Surfaces (TPMS-Gyroid) and the signed distance field (SDF)
Haja-Sherief N Musthafa
Abstract
Haja-Sherief N Musthafa
Abstract
Design of Bone Tissue Engineering scaffolds using Triply Periodic Minimal Surfaces (TPMS) and the signed distance field (SDF) : 1.) PS200 : Pore Size 200 µm and Strut Size 200 µm 2.) PS350 : Pore Size 350 µm and Strut Size 200 µm 3.) PS550 : Pore Size 550 µm and Strut Size 200 µm 4.) PS750 : Pore Size 750 µm and Strut Size 200 µm 5.) PS1000 : Pore Size 1000 µm and Strut Size 200 µm For Both Design and Finite Element Modeling Dataset is given below : N Musthafa, Haja-Sherief. "Design and Finite Element Analysis of Triply Periodic Minimal Surfaces (gyroid) Scaffolds". Zenodo, August 23, 2023. https://doi.org/10.5281/zenodo.8276799 The related scientific article is given below: N. Musthafa, Haja-Sherief et al. 2023. "In-Silico Prediction of Mechanical Behaviour of Uniform Gyroid Scaffolds Affected by Its Design Parameters for Bone Tissue Engineering Applications" Computation 11, no. 9: 181. https://doi.org/10.3390/computation11090181
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Design of Bone Tissue Engineering scaffolds using Triply Periodic Minimal Surfaces (TPMS) and the signed distance field (SDF) : 1.) PS200 : Pore Size 200 µm and Strut Size 200 µm 2.) PS350 : Pore Size 350 µm and Strut Size 200 µm 3.) PS550 : Pore Size 550 µm and Strut Size 200 µm 4.) PS750 : Pore Size 750 µm and Strut Size 200 µm 5.) PS1000 : Pore Size 1000 µm and Strut Size 200 µm For Both Design and Finite Element Modeling Dataset is given below : N Musthafa, Haja-Sherief. "Design and Finite Element Analysis of Triply Periodic Minimal Surfaces (gyroid) Scaffolds". Zenodo, August 23, 2023. https://doi.org/10.5281/zenodo.8276799 The related scientific article is given below: N. Musthafa, Haja-Sherief et al. 2023. "In-Silico Prediction of Mechanical Behaviour of Uniform Gyroid Scaffolds Affected by Its Design Parameters for Bone Tissue Engineering Applications" Computation 11, no. 9: 181. https://doi.org/10.3390/computation11090181
Key concepts: Gyroid, Minimal surface, Tissue engineering, Field (mathematics), Biomedical engineering, Materials science, Engineering, Chemistry