2024Clinica Chimica ActaOpen access

Usefulness and analytical performances of complement multiplex assay for measuring complement biomarkers in plasma

Marie-Sophie Meuleman, Anna Duval, Anne Grünenwald, Mikel Rezola Artero, Mohamed Dermani, Julie Peliconi, Margot Revel, Paula Vieira-Martins, Marie Courbebaisse, Béatrice Parfait, David Lebeaux, Gérard Friedlander, Lubka T. Roumenina, Sophie Chauvet, Véronique Frémeaux‐Bacchi, Marie‐Agnès Dragon‐Durey

Open full text 17 citations

Abstract

This record does not include an abstract. Use the full-text link above if available.

Open-access reader

About this research paper

What this paper is about

An abstract is not available in the OpenAlex record for this paper.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Key concepts: Complement system, C4A, Complement (music), Multiplex, Alternative complement pathway, Complement component 5, Factor H, Immunology

Related papers

Back to paper searchBrowse research topicsOriginal source
Usefulness and analytical performances of complement multiplex assay for measuring complement biomarkers in plasma — Research Paper | ScholarLens