2023•DiagnosticsOpen access

The Benefit of Air Conduction Pure-Tone Audiometry as a Screening Method for Hearing Loss over the VAS Score

Aris Ι. Giotakis, Lambros Mariolis, Ioannis Koulentis, Christos Mpoutris, Evangelos I Giotakis, Aikaterini Apostolopoulou, Efstathios Papaefstathiou

Open full text 1 citations

Abstract

Hearing loss is commonly encountered by general practitioners. We aimed to evaluate the screening benefit of air conduction pure-tone audiometry over visual analogue scale (VAS) scores for hearing loss. Moreover, we intended to perform the first cross-sectional study in Greece to assess hearing loss with pure-tone audiometry in young adults of the general population. We evaluated Greeks between 15 and 40 years old in a high school in Karditsa, Greece, and a primary health care unit in a nearby community. Subjects filled out a VAS score sheet and underwent pure-tone audiometry in a room without sound isolation, with air conduction only. We named the latter procedure modified pure-tone audiometry (mPTA). Subjects with pathologic results were examined via otoscopy and standardized pure-tone audiometry (sPTA). Of the 286 subjects evaluated, the VAS score revealed 5 subjects (1.7%) with hearing loss. mPTA (100 s duration) doubled this percentage (in total 3.8%; Pearson Chi-Square test; p < 0.001). Based on sPTA, the sensitivity and positive predictive value of the VAS score were 40% and 13%, respectively. For mPTA, they were 100% and 37%, respectively. mPTA filtered out pathologic cases in a proper, rapid, cheap and simple way and may be considered a proper screening method for hearing loss in primary health care.

Open-access reader

About this research paper

What this paper is about

Hearing loss is commonly encountered by general practitioners. We aimed to evaluate the screening benefit of air conduction pure-tone audiometry over visual analogue scale (VAS) scores for hearing loss. Moreover, we intended to perform the first cross-sectional study in Greece to assess hearing loss with pure-tone audiometry in young adults of the general population. We evaluated Greeks between 15 and 40 years old in a high school in Karditsa, Greece, and a primary health care unit in a nearby community. Subjects filled out a VAS score sheet and underwent pure-tone audiometry in a room without sound isolation, with air conduction only. We named the latter procedure modified pure-tone audiometry (mPTA). Subjects with pathologic results were examined via otoscopy and standardized pure-tone audiometry (sPTA). Of the 286 subjects evaluated, the VAS score revealed 5 subjects (1.7%) with hearing loss. mPTA (100 s duration) doubled this percentage (in total 3.8%; Pearson Chi-Square test; p < 0.001). Based on sPTA, the sensitivity and positive predictive value of the VAS score were 40% and 13%, respectively. For mPTA, they were 100% and 37%, respectively. mPTA filtered out pathologic cases in a proper, rapid, cheap and simple way and may be considered a proper screening method for hearing loss in primary health care.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Hearing loss is commonly encountered by general practitioners. We aimed to evaluate the screening benefit of air conduction pure-tone audiometry over visual analogue scale (VAS) scores for hearing loss. Moreover, we intended to perform the first cross-sectional study in Greece to assess hearing loss with pure-tone audiometry in young adults of the general population. We evaluated Greeks between 15 and 40 years old in a high school in Karditsa, Greece, and a primary health care unit in a nearby community. Subjects filled out a VAS score sheet and underwent pure-tone audiometry in a room without sound isolation, with air conduction only. We named the latter procedure modified pure-tone audiometry (mPTA). Subjects with pathologic results were examined via otoscopy and standardized pure-tone audiometry (sPTA). Of the 286 subjects evaluated, the VAS score revealed 5 subjects (1.7%) with hearing loss. mPTA (100 s duration) doubled this percentage (in total 3.8%; Pearson Chi-Square test; p < 0.001). Based on sPTA, the sensitivity and positive predictive value of the VAS score were 40% and 13%, respectively. For mPTA, they were 100% and 37%, respectively. mPTA filtered out pathologic cases in a proper, rapid, cheap and simple way and may be considered a proper screening method for hearing loss in primary health care.

Key concepts: Pure tone audiometry, Audiometry, Medicine, Audiology, Hearing loss, Visual analogue scale, Pure tone, Hearing test

Related papers

Back to paper searchBrowse research topicsOriginal source
The Benefit of Air Conduction Pure-Tone Audiometry as a Screening Method for Hearing Loss over the VAS Score — Research Paper | ScholarLens