2023•Preprints.orgOpen access

Rethinking the Use of Linear Forms of the Langmuir Isotherm in Adsorption Modeling to Calculate Langmuir Isotherm Parameters

Rohollah Ezzati

Open full text 4 citations

Abstract

The Langmuir isotherm is a widely used model for analyzing adsorption equilibrium data. This study evaluated the efficiency and accuracy of all four linear forms of the Langmuir isotherm and its non-linear form using 67 experimental data sets selected from the literature. The results showed that only if all four linear forms simultaneously show high accuracy, then the non-linear form also shows high accuracy, and therefore it can be said that the process probably follows the Langmuir isotherm. On the contrary, when at least one of the four linear forms of the Langmuir isotherm has low accuracy, it means that the non-linear form also has low accuracy, and it can be concluded that this process does not follow the Langmuir isotherm. This research suggests that all four linear forms of the Langmuir isotherm should be evaluated simultaneously to conclude whether the studied system follows the Langmuir isotherm or not. In other words, relying on only one of the four linear forms of the Langmuir isotherm to model adsorption and calculate the Langmuir constant and maximum adsorption capacity is an incomplete approach, contrary to the conventional approach.

Open-access reader

About this research paper

What this paper is about

The Langmuir isotherm is a widely used model for analyzing adsorption equilibrium data. This study evaluated the efficiency and accuracy of all four linear forms of the Langmuir isotherm and its non-linear form using 67 experimental data sets selected from the literature. The results showed that only if all four linear forms simultaneously show high accuracy, then the non-linear form also shows high accuracy, and therefore it can be said that the process probably follows the Langmuir isotherm. On the contrary, when at least one of the four linear forms of the Langmuir isotherm has low accuracy, it means that the non-linear form also has low accuracy, and it can be concluded that this process does not follow the Langmuir isotherm. This research suggests that all four linear forms of the Langmuir isotherm should be evaluated simultaneously to conclude whether the studied system follows the Langmuir isotherm or not. In other words, relying on only one of the four linear forms of the Langmuir isotherm to model adsorption and calculate the Langmuir constant and maximum adsorption capacity is an incomplete approach, contrary to the conventional approach.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The Langmuir isotherm is a widely used model for analyzing adsorption equilibrium data. This study evaluated the efficiency and accuracy of all four linear forms of the Langmuir isotherm and its non-linear form using 67 experimental data sets selected from the literature. The results showed that only if all four linear forms simultaneously show high accuracy, then the non-linear form also shows high accuracy, and therefore it can be said that the process probably follows the Langmuir isotherm. On the contrary, when at least one of the four linear forms of the Langmuir isotherm has low accuracy, it means that the non-linear form also has low accuracy, and it can be concluded that this process does not follow the Langmuir isotherm. This research suggests that all four linear forms of the Langmuir isotherm should be evaluated simultaneously to conclude whether the studied system follows the Langmuir isotherm or not. In other words, relying on only one of the four linear forms of the Langmuir isotherm to model adsorption and calculate the Langmuir constant and maximum adsorption capacity is an incomplete approach, contrary to the conventional approach.

Key concepts: Langmuir adsorption model, Langmuir, Adsorption, Sorption isotherm, Thermodynamics, Freundlich equation, Chemistry, Linear equation

Related papers

Back to paper searchBrowse research topicsOriginal source
Rethinking the Use of Linear Forms of the Langmuir Isotherm in Adsorption Modeling to Calculate Langmuir Isotherm Parameters — Research Paper | ScholarLens