2023Arrhythmia & Electrophysiology ReviewOpen access

Very-high-power Short-duration Ablation versus Conventional Ablation for Pulmonary Vein Isolation in Atrial Fibrillation: Systematic Review and Meta-analysis

Raymond Pranata, Giky Karwiky, Mohammad Iqbal

Open full text 13 citations

Abstract

The aim of this study was to compare the effectiveness and safety of very-high-power short-duration (VHPSD) ablation (70-90 W/4-7 s) with conventional ablation (30-40 W/>20 s, 50 W/7-11 s) for pulmonary vein isolation (PVI) in patients with AF. A total of 13 studies were included in this analysis (1,527 patients). AF recurrence occurred in 14% (95% CI [11-18%]) of the VHPSD group. VHPSD was associated with lower AF recurrence (OR 0.65; 95% CI [0.48-0.89]; p=0.006) compared with the conventional ablation group. Subgroup analysis showed that additional ablation beyond PVI had a similar rate of AF recurrence (16% versus 10%) compared with PVI alone. Procedure and ablation durations were significantly shorter in the VHPSD group with a mean differences of -14.4 minutes (p=0.017) and -14.1 minutes (p<0.001), respectively. Complications occurred in 6% (95% CI [3-9%]) of the VHPSD group, and the rate was similar between the two groups (OR 1.03; 95% CI [0.60-1.80]; p=0.498). VHPSD ablation resulted in less AF recurrence and a shorter procedure time. Additional ablation beyond PVI alone in VHPSD may not provide additional benefits.

Open-access reader

About this research paper

What this paper is about

The aim of this study was to compare the effectiveness and safety of very-high-power short-duration (VHPSD) ablation (70-90 W/4-7 s) with conventional ablation (30-40 W/>20 s, 50 W/7-11 s) for pulmonary vein isolation (PVI) in patients with AF. A total of 13 studies were included in this analysis (1,527 patients). AF recurrence occurred in 14% (95% CI [11-18%]) of the VHPSD group. VHPSD was associated with lower AF recurrence (OR 0.65; 95% CI [0.48-0.89]; p=0.006) compared with the conventional ablation group. Subgroup analysis showed that additional ablation beyond PVI had a similar rate of AF recurrence (16% versus 10%) compared with PVI alone. Procedure and ablation durations were significantly shorter in the VHPSD group with a mean differences of -14.4 minutes (p=0.017) and -14.1 minutes (p<0.001), respectively. Complications occurred in 6% (95% CI [3-9%]) of the VHPSD group, and the rate was similar between the two groups (OR 1.03; 95% CI [0.60-1.80]; p=0.498). VHPSD ablation resulted in less AF recurrence and a shorter procedure time. Additional ablation beyond PVI alone in VHPSD may not provide additional benefits.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The aim of this study was to compare the effectiveness and safety of very-high-power short-duration (VHPSD) ablation (70-90 W/4-7 s) with conventional ablation (30-40 W/>20 s, 50 W/7-11 s) for pulmonary vein isolation (PVI) in patients with AF. A total of 13 studies were included in this analysis (1,527 patients). AF recurrence occurred in 14% (95% CI [11-18%]) of the VHPSD group. VHPSD was associated with lower AF recurrence (OR 0.65; 95% CI [0.48-0.89]; p=0.006) compared with the conventional ablation group. Subgroup analysis showed that additional ablation beyond PVI had a similar rate of AF recurrence (16% versus 10%) compared with PVI alone. Procedure and ablation durations were significantly shorter in the VHPSD group with a mean differences of -14.4 minutes (p=0.017) and -14.1 minutes (p<0.001), respectively. Complications occurred in 6% (95% CI [3-9%]) of the VHPSD group, and the rate was similar between the two groups (OR 1.03; 95% CI [0.60-1.80]; p=0.498). VHPSD ablation resulted in less AF recurrence and a shorter procedure time. Additional ablation beyond PVI alone in VHPSD may not provide additional benefits.

Key concepts: Ablation, Pulmonary vein, Atrial fibrillation, Medicine, Cardiology, Internal medicine, Catheter ablation, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Very-high-power Short-duration Ablation versus Conventional Ablation for Pulmonary Vein Isolation in Atrial Fibrillation: Systematic Review and Meta-analysis — Research Paper | ScholarLens