2023Clinical Advances in PeriodonticsOpen access

A pattern of peri‐implantitis affecting middle implants in 3‐implant splinted prostheses

Braedan R J Prete, Michael AJ Silva, Brian Wong, Douglas Deporter

Open full text 2 citations

Abstract

BACKGROUND: Previous investigators have noted an increased risk of crestal bone loss and failure of the middle implant of 3-implant-splinted (3-IS) fixed dental prostheses (FDPs). Possible causes have included ill-fitting prostheses, unhygienic prosthetic contours, and discrepancies in prosthetic platform heights. METHODS & RESULTS: We identified four cases in which the middle implant of a 3-IS multiunit FDP suffered advanced bone loss, ultimately leading to implant removal. While more than one possible risk for implant failure existed in each case, a common thread was that the prosthetic platform of the middle implant for all patients was coronally positioned relative to the corresponding mesial and/or distal implants. CONCLUSIONS: Splinting three adjacent implants into one prosthesis may add risk for a variety of reasons possibly including small differences in the heights of the three prosthetic tables. KEY POINTS: Why are these cases new information? Our observations suggest that discrepancies between implant prosthetic platforms supporting 3-implant splinted, multiunit FDPs may be an added risk factor for middle implant failure. What are the keys to successful management of these cases? It is possible that small differences in apico-coronal implant positioning with 3-implant splinted multiunit FDPs may affect the success of the middle implants. What are the primary limitations to success in these cases? There is limited literature involving precise protocols and long-term outcomes of 3-implant splinted implant restorations. Studies comparing 3-implant splinted FDPs to other configurations are needed.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: Previous investigators have noted an increased risk of crestal bone loss and failure of the middle implant of 3-implant-splinted (3-IS) fixed dental prostheses (FDPs). Possible causes have included ill-fitting prostheses, unhygienic prosthetic contours, and discrepancies in prosthetic platform heights. METHODS & RESULTS: We identified four cases in which the middle implant of a 3-IS multiunit FDP suffered advanced bone loss, ultimately leading to implant removal. While more than one possible risk for implant failure existed in each case, a common thread was that the prosthetic platform of the middle implant for all patients was coronally positioned relative to the corresponding mesial and/or distal implants. CONCLUSIONS: Splinting three adjacent implants into one prosthesis may add risk for a variety of reasons possibly including small differences in the heights of the three prosthetic tables. KEY POINTS: Why are these cases new information? Our observations suggest that discrepancies between implant prosthetic platforms supporting 3-implant splinted, multiunit FDPs may be an added risk factor for middle implant failure. What are the keys to successful management of these cases? It is possible that small differences in apico-coronal implant positioning with 3-implant splinted multiunit FDPs may affect the success of the middle implants. What are the primary limitations to success in these cases? There is limited literature involving precise protocols and long-term outcomes of 3-implant splinted implant restorations. Studies comparing 3-implant splinted FDPs to other configurations are needed.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Previous investigators have noted an increased risk of crestal bone loss and failure of the middle implant of 3-implant-splinted (3-IS) fixed dental prostheses (FDPs). Possible causes have included ill-fitting prostheses, unhygienic prosthetic contours, and discrepancies in prosthetic platform heights. METHODS & RESULTS: We identified four cases in which the middle implant of a 3-IS multiunit FDP suffered advanced bone loss, ultimately leading to implant removal. While more than one possible risk for implant failure existed in each case, a common thread was that the prosthetic platform of the middle implant for all patients was coronally positioned relative to the corresponding mesial and/or distal implants. CONCLUSIONS: Splinting three adjacent implants into one prosthesis may add risk for a variety of reasons possibly including small differences in the heights of the three prosthetic tables. KEY POINTS: Why are these cases new information? Our observations suggest that discrepancies between implant prosthetic platforms supporting 3-implant splinted, multiunit FDPs may be an added risk factor for middle implant failure. What are the keys to successful management of these cases? It is possible that small differences in apico-coronal implant positioning with 3-implant splinted multiunit FDPs may affect the success of the middle implants. What are the primary limitations to success in these cases? There is limited literature involving precise protocols and long-term outcomes of 3-implant splinted implant restorations. Studies comparing 3-implant splinted FDPs to other configurations are needed.

Key concepts: Peri-implantitis, Medicine, Dentistry, Implant, Orthodontics, Dental prosthesis, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
A pattern of peri‐implantitis affecting middle implants in 3‐implant splinted prostheses — Research Paper | ScholarLens