Single-tuned passive filter (STPF) for mitigating harmonics in a 3-phase power system
Meshack Magaji Ishaya, Oluwatayomi Rereloluwa Adegboye, Ephraim Bonah Agyekum, Mohamed F. Elnaggar, Mohammed M. Alrashed, Salah Kamel
Abstract
Meshack Magaji Ishaya, Oluwatayomi Rereloluwa Adegboye, Ephraim Bonah Agyekum, Mohamed F. Elnaggar, Mohammed M. Alrashed, Salah Kamel
Abstract
Numerous integrals of the fundamental frequency are known as harmonics and can be found in power systems or electrical circuitry systems. Non-linear loads occasionally drain current or contains a varying impedance with each period of the AC voltage are often responsible for power system harmonics. This can result in system overheating, system losses, and equipment or system damage. In order to achieve the IEEE 519 power quality standard, filters are routinely employed to lower harmonic levels. In this work, we designed a single tuned passive filter (STPF) to minimize harmonics of sequence 5th, 7th, 11th, 13th, 17th, and 19th in a three (3) phase power system. The measurements were taken at the point of common coupling. To test the filter performance, the system and STPF were designed in MATLAB/Simulink, and the simulated results produced without and with STPF were compared. The [Formula: see text] was reduced from 14.93% down to 4.87% when STPF was connected which is within the IEEE 519-2022 standard; proving that the STPF was effective in decreasing the harmonics to the desired level.
OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Numerous integrals of the fundamental frequency are known as harmonics and can be found in power systems or electrical circuitry systems. Non-linear loads occasionally drain current or contains a varying impedance with each period of the AC voltage are often responsible for power system harmonics. This can result in system overheating, system losses, and equipment or system damage. In order to achieve the IEEE 519 power quality standard, filters are routinely employed to lower harmonic levels. In this work, we designed a single tuned passive filter (STPF) to minimize harmonics of sequence 5th, 7th, 11th, 13th, 17th, and 19th in a three (3) phase power system. The measurements were taken at the point of common coupling. To test the filter performance, the system and STPF were designed in MATLAB/Simulink, and the simulated results produced without and with STPF were compared. The [Formula: see text] was reduced from 14.93% down to 4.87% when STPF was connected which is within the IEEE 519-2022 standard; proving that the STPF was effective in decreasing the harmonics to the desired level.
Key concepts: Harmonics, Electric power system, Electronic filter, Computer science, Harmonic, Electrical impedance, MATLAB, Control theory (sociology)