2023IEEE Sensors JournalRequires access

Fast Response Infrared Detector Using a Radially Distributed Dual-Layer Thermopile

Zhaohui Yang, Gaobin Xu, Shirong Chen, Jianguo Feng, Xing Chen, Yuanming Ma, Yongqiang Yu, Baichuan Sun

Open publisher page 10 citations

Abstract

Microelectromechanical system (MEMS) thermopile infrared (IR) detectors excel in contactless, highly sensitive, noninvasive temperature measurements over a wide range, without cooling systems, making them ideal for precise intelligent sensing applications. In this study, we present a micromachined thermopile IR detector utilizing a radially distributed dual-layer thermopile that demonstrates fast response time and significantly improved responsivity and detectivity. A dual-layer thermocouple array is designed by applying the N-/P-poly, which is radially distributed on a SiO2 supporting layer and suspended by dry etching the backside of a silicon substrate. The results of the study, which compared traditional four-ended beam structures with radially distributed structures that were modeled and simulated, indicate that the latter design enhances the output voltage and significantly improves responsivity and detectivity, with an increase of 40.5% and 43.8%, respectively. With a fast response time of 9.5 ms at room temperature, the detector exhibited a measured responsivity of 100.6 V/W and detectivity of$5.2\times107$cm$\cdot $Hz1/2/W in an experimental system constructed to evaluate its performance.

About this research paper

What this paper is about

Microelectromechanical system (MEMS) thermopile infrared (IR) detectors excel in contactless, highly sensitive, noninvasive temperature measurements over a wide range, without cooling systems, making them ideal for precise intelligent sensing applications. In this study, we present a micromachined thermopile IR detector utilizing a radially distributed dual-layer thermopile that demonstrates fast response time and significantly improved responsivity and detectivity. A dual-layer thermocouple array is designed by applying the N-/P-poly, which is radially distributed on a SiO2 supporting layer and suspended by dry etching the backside of a silicon substrate. The results of the study, which compared traditional four-ended beam structures with radially distributed structures that were modeled and simulated, indicate that the latter design enhances the output voltage and significantly improves responsivity and detectivity, with an increase of 40.5% and 43.8%, respectively. With a fast response time of 9.5 ms at room temperature, the detector exhibited a measured responsivity of 100.6 V/W and detectivity of$5.2\times107$cm$\cdot $Hz1/2/W in an experimental system constructed to evaluate its performance.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Microelectromechanical system (MEMS) thermopile infrared (IR) detectors excel in contactless, highly sensitive, noninvasive temperature measurements over a wide range, without cooling systems, making them ideal for precise intelligent sensing applications. In this study, we present a micromachined thermopile IR detector utilizing a radially distributed dual-layer thermopile that demonstrates fast response time and significantly improved responsivity and detectivity. A dual-layer thermocouple array is designed by applying the N-/P-poly, which is radially distributed on a SiO2 supporting layer and suspended by dry etching the backside of a silicon substrate. The results of the study, which compared traditional four-ended beam structures with radially distributed structures that were modeled and simulated, indicate that the latter design enhances the output voltage and significantly improves responsivity and detectivity, with an increase of 40.5% and 43.8%, respectively. With a fast response time of 9.5 ms at room temperature, the detector exhibited a measured responsivity of 100.6 V/W and detectivity of$5.2\times107$cm$\cdot $Hz1/2/W in an experimental system constructed to evaluate its performance.

Key concepts: Thermopile, Responsivity, Thermocouple, Materials science, Optoelectronics, Detector, Response time, Specific detectivity

Related papers

Back to paper searchBrowse research topicsOriginal source
Fast Response Infrared Detector Using a Radially Distributed Dual-Layer Thermopile — Research Paper | ScholarLens