2023•MachinesOpen access

Estimation Technique for IGBT Module Junction Temperature in a High-Power Density Inverter

Ahmed H. Okilly, Seungdeog Choi, Sangshin Kwak, Namhun Kim, Jonghyuk Lee, Hyoungjun Moon, Jeihoon Baek

Open full text 13 citations

Abstract

During the last few decades, insulated-gate bipolar transistor (IGBT) power modules have evolved as reliable and useful electronic parts due to the increasing relevance of power inverters in power infrastructure, reliability enhancement, and long-life operation. Excessive temperature stresses caused by excessive power losses frequently cause high-power-density IGBT modules to fail. As a result, module temperature monitoring techniques are critical in designing and selecting IGBT modules for high-power-density applications to guarantee that temperature stresses in the various module components remain within the rated values. In this paper, a module’s different losses were estimated, a heating pipe system for the thermal power cycling technique was proposed, and finite element method (FEM) thermal modeling and module temperature measurement were performed using ANSYS Icepak software version 2022 R1 to determine whether the IGBT module’s temperature rise was within acceptable bounds. To test the proposed technique, a proposed design structure of the practical railway application with a 3.3 MW traction inverter is introduced using commercialized IGBT modules from Semikron company with maximum temperature of about 150 °C. the FEM analysis results showed that the maximum junction temperature is about 109 °C which is in acceptable ranges, confirming the appropriate selection of the employed IGBT module for the target application.

Open-access reader

About this research paper

What this paper is about

During the last few decades, insulated-gate bipolar transistor (IGBT) power modules have evolved as reliable and useful electronic parts due to the increasing relevance of power inverters in power infrastructure, reliability enhancement, and long-life operation. Excessive temperature stresses caused by excessive power losses frequently cause high-power-density IGBT modules to fail. As a result, module temperature monitoring techniques are critical in designing and selecting IGBT modules for high-power-density applications to guarantee that temperature stresses in the various module components remain within the rated values. In this paper, a module’s different losses were estimated, a heating pipe system for the thermal power cycling technique was proposed, and finite element method (FEM) thermal modeling and module temperature measurement were performed using ANSYS Icepak software version 2022 R1 to determine whether the IGBT module’s temperature rise was within acceptable bounds. To test the proposed technique, a proposed design structure of the practical railway application with a 3.3 MW traction inverter is introduced using commercialized IGBT modules from Semikron company with maximum temperature of about 150 °C. the FEM analysis results showed that the maximum junction temperature is about 109 °C which is in acceptable ranges, confirming the appropriate selection of the employed IGBT module for the target application.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

During the last few decades, insulated-gate bipolar transistor (IGBT) power modules have evolved as reliable and useful electronic parts due to the increasing relevance of power inverters in power infrastructure, reliability enhancement, and long-life operation. Excessive temperature stresses caused by excessive power losses frequently cause high-power-density IGBT modules to fail. As a result, module temperature monitoring techniques are critical in designing and selecting IGBT modules for high-power-density applications to guarantee that temperature stresses in the various module components remain within the rated values. In this paper, a module’s different losses were estimated, a heating pipe system for the thermal power cycling technique was proposed, and finite element method (FEM) thermal modeling and module temperature measurement were performed using ANSYS Icepak software version 2022 R1 to determine whether the IGBT module’s temperature rise was within acceptable bounds. To test the proposed technique, a proposed design structure of the practical railway application with a 3.3 MW traction inverter is introduced using commercialized IGBT modules from Semikron company with maximum temperature of about 150 °C. the FEM analysis results showed that the maximum junction temperature is about 109 °C which is in acceptable ranges, confirming the appropriate selection of the employed IGBT module for the target application.

Key concepts: Insulated-gate bipolar transistor, Junction temperature, Power module, Power density, Power (physics), Power cycling, Finite element method, Power semiconductor device

Related papers

Back to paper searchBrowse research topicsOriginal source
Estimation Technique for IGBT Module Junction Temperature in a High-Power Density Inverter — Research Paper | ScholarLens