2023Journal of Engineering ResearchOpen access

The impact of window orientation, glazing, and window-to-wall ratio on the heating and cooling energy of an office building: The case of hot and semi-arid climate

Ahmed Emad Ahmed, Mahmood Sh. Suwaed, Ahmed Mohammed Shakir, Ahmed Ghareeb

Open full text 55 citations

Abstract

Adopting suitable design strategies in buildings throughout the design stage provides increased energy-saving potential. In this study, factors influencing window design, such as the window-to-wall ratio (WWR) and window orientation, along with different glazing materials, are being investigated in the city of Kirkuk, Iraq for possible energy consumption reduction. The study presents a simulation-based analysis on a typical office building in the area; evaluating four WWRs, four orientations, and three window glazing materials, e.g., clear, gray, and theoretical, as well as single and double-glazed windows. The results indicate that minimum heating consumption could be achieved with double clear glass for south-facing windows if WWR was 100%. For north-facing windows, minimum cooling consumption is achieved with double theoretical-197 glass with a 25% WWR. These measures can be utilized by architects and construction managers to communicate information to customers in an understandable manner and make better window design decisions.

About this research paper

What this paper is about

Adopting suitable design strategies in buildings throughout the design stage provides increased energy-saving potential. In this study, factors influencing window design, such as the window-to-wall ratio (WWR) and window orientation, along with different glazing materials, are being investigated in the city of Kirkuk, Iraq for possible energy consumption reduction. The study presents a simulation-based analysis on a typical office building in the area; evaluating four WWRs, four orientations, and three window glazing materials, e.g., clear, gray, and theoretical, as well as single and double-glazed windows. The results indicate that minimum heating consumption could be achieved with double clear glass for south-facing windows if WWR was 100%. For north-facing windows, minimum cooling consumption is achieved with double theoretical-197 glass with a 25% WWR. These measures can be utilized by architects and construction managers to communicate information to customers in an understandable manner and make better window design decisions.

Why it matters

OpenAlex reports 55 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Adopting suitable design strategies in buildings throughout the design stage provides increased energy-saving potential. In this study, factors influencing window design, such as the window-to-wall ratio (WWR) and window orientation, along with different glazing materials, are being investigated in the city of Kirkuk, Iraq for possible energy consumption reduction. The study presents a simulation-based analysis on a typical office building in the area; evaluating four WWRs, four orientations, and three window glazing materials, e.g., clear, gray, and theoretical, as well as single and double-glazed windows. The results indicate that minimum heating consumption could be achieved with double clear glass for south-facing windows if WWR was 100%. For north-facing windows, minimum cooling consumption is achieved with double theoretical-197 glass with a 25% WWR. These measures can be utilized by architects and construction managers to communicate information to customers in an understandable manner and make better window design decisions.

Key concepts: Glazing, Window (computing), Architectural engineering, Energy consumption, Orientation (vector space), Solar gain, Consumption (sociology), Window of opportunity

Related papers

Back to paper searchBrowse research topicsOriginal source
The impact of window orientation, glazing, and window-to-wall ratio on the heating and cooling energy of an office building: The case of hot and semi-arid climate — Research Paper | ScholarLens