2023•ERJ Open ResearchOpen access

Pulmonary radioaerosol mucociliary clearance assessment: searching for genotype-specific differences and potential as an outcome measure in primary ciliary dyskinesia

June Kehlet Marthin, Mathias Geldermann Holgersen, Kim G. Nielsen, Jann Mortensen

Open full text 8 citations

Abstract

Background Pulmonary radioaerosol mucociliary clearance (PRMC) is a reliable method for assessingin vivowhole lung mucociliary clearance and has been used at the Danish PCD Centre as a supplementary diagnostic test for primary ciliary dyskinesia (PCD) for more than two decades. This study aimed to investigate genotype-specific differences in PRMC measures and evaluate its potential as an outcome parameter. Material and methods The study was based on a retrospective analysis of PRMC tests performed over a 24-year period (1999–2022) in individuals referred for PCD work-up and included patients with genetically confirmed PCD and non-PCD controls. Patients inhaled nebulised technetium-albumin-colloid before static and dynamic imaging was obtained. Three parameters were evaluated: 1-h lung retention (LR1), tracheobronchial velocity (TBV) and cough clearance. Results The study included 69 patients from the Danish PCD cohort, representing 26 different PCD genotypes. Mucociliary clearance by PRMC was consistently absent in most PCD patients, regardless of genotype. However, a single patient with aCCDC103mutation, preserved ciliary function and normal nasal nitric oxide levels exhibited normal LR1 and low TBV values. Voluntary cough significantly improved clearance, with a median improvement of 11% (interquartile range 4–24%). Conclusion Absent mucociliary clearance by PRMC should be expected in PCD regardless of genotype but residual ciliary function could result in measurable PRMC. This indicates a potential for PRMC to detect improvements in ciliary function if this can be restored. Addressing involuntary cough and peripheral deposition of radioaerosol is important if PRMC is to be used as an outcome measure in future clinical PCD trials.

Open-access reader

About this research paper

What this paper is about

Background Pulmonary radioaerosol mucociliary clearance (PRMC) is a reliable method for assessingin vivowhole lung mucociliary clearance and has been used at the Danish PCD Centre as a supplementary diagnostic test for primary ciliary dyskinesia (PCD) for more than two decades. This study aimed to investigate genotype-specific differences in PRMC measures and evaluate its potential as an outcome parameter. Material and methods The study was based on a retrospective analysis of PRMC tests performed over a 24-year period (1999–2022) in individuals referred for PCD work-up and included patients with genetically confirmed PCD and non-PCD controls. Patients inhaled nebulised technetium-albumin-colloid before static and dynamic imaging was obtained. Three parameters were evaluated: 1-h lung retention (LR1), tracheobronchial velocity (TBV) and cough clearance. Results The study included 69 patients from the Danish PCD cohort, representing 26 different PCD genotypes. Mucociliary clearance by PRMC was consistently absent in most PCD patients, regardless of genotype. However, a single patient with aCCDC103mutation, preserved ciliary function and normal nasal nitric oxide levels exhibited normal LR1 and low TBV values. Voluntary cough significantly improved clearance, with a median improvement of 11% (interquartile range 4–24%). Conclusion Absent mucociliary clearance by PRMC should be expected in PCD regardless of genotype but residual ciliary function could result in measurable PRMC. This indicates a potential for PRMC to detect improvements in ciliary function if this can be restored. Addressing involuntary cough and peripheral deposition of radioaerosol is important if PRMC is to be used as an outcome measure in future clinical PCD trials.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background Pulmonary radioaerosol mucociliary clearance (PRMC) is a reliable method for assessingin vivowhole lung mucociliary clearance and has been used at the Danish PCD Centre as a supplementary diagnostic test for primary ciliary dyskinesia (PCD) for more than two decades. This study aimed to investigate genotype-specific differences in PRMC measures and evaluate its potential as an outcome parameter. Material and methods The study was based on a retrospective analysis of PRMC tests performed over a 24-year period (1999–2022) in individuals referred for PCD work-up and included patients with genetically confirmed PCD and non-PCD controls. Patients inhaled nebulised technetium-albumin-colloid before static and dynamic imaging was obtained. Three parameters were evaluated: 1-h lung retention (LR1), tracheobronchial velocity (TBV) and cough clearance. Results The study included 69 patients from the Danish PCD cohort, representing 26 different PCD genotypes. Mucociliary clearance by PRMC was consistently absent in most PCD patients, regardless of genotype. However, a single patient with aCCDC103mutation, preserved ciliary function and normal nasal nitric oxide levels exhibited normal LR1 and low TBV values. Voluntary cough significantly improved clearance, with a median improvement of 11% (interquartile range 4–24%). Conclusion Absent mucociliary clearance by PRMC should be expected in PCD regardless of genotype but residual ciliary function could result in measurable PRMC. This indicates a potential for PRMC to detect improvements in ciliary function if this can be restored. Addressing involuntary cough and peripheral deposition of radioaerosol is important if PRMC is to be used as an outcome measure in future clinical PCD trials.

Key concepts: Primary ciliary dyskinesia, Mucociliary clearance, Medicine, Interquartile range, Pulmonary function testing, Lung, Gastroenterology, Genotype

Related papers

Back to paper searchBrowse research topicsOriginal source
Pulmonary radioaerosol mucociliary clearance assessment: searching for genotype-specific differences and potential as an outcome measure in primary ciliary dyskinesia — Research Paper | ScholarLens