2023Radiation Protection DosimetryRequires access

γ-H2AX and phospho-ATM enzyme-linked immunosorbent assays as biodosimetry methods for radiation exposure assessment: a pilot study

Dwi Ramadhani, Devita Tetriana, Sofiati Purnami, Viria Agesti Suvifan, Iin Kurnia Hasan Basri, Teja Kisnanto, Tiara Andalya Oktariyani, Dira Syafira, Muhamad Yasin Yunus, Tomisato Miura, Mukh Syaifudin, Retno Sari Widowati

Open publisher page 4 citations

Abstract

In the event of a radiological incident, a fast and accurate biological dosimetry (biodosimetry) method for evaluating people who have been potentially exposed to ionising radiation is crucial. Among the many biodosimetry methods available, the immunodetection of phosphorylated H2AX (γ-H2AX) stands as a promising method to be used in the triage of patients exposed to radiation. Currently, the most common way to measure γ-H2AX levels is through fluorescence microscopy. In this pilot study, we assessed the feasibility of using an enzyme-linked immunosorbent assay (ELISA) for quantifying γ-H2AX for biodosimetry purposes. Moreover, the usefulness of measuring phosphorylated ATM (pATM) levels through ELISA for biodosimetry was also evaluated. Blood samples were obtained from three male donors (38 y) and were irradiated with 60Co (0, 1, 2 and 6 Gy). Peripheral blood mononuclear cells (PBMCs) were isolated and lysed before measuring γ-H2AX, total H2AX protein and pATM using ELISA kits. The dicentric chromosome assay (DCA) using whole blood was also performed for comparison. Data from all donors at each dose were pooled before statistical analysis. The ratio of γ-H2AX/total H2AX and pATM levels increased in a radiation-dose-dependent manner. The average γ-H2AX/total H2AX ratios were 0.816 ± 0.219, 0.830 ± 0.685, 1.276 ± 1.151 and 1.606 ± 1.098, whereas the average levels of pATM were 59.359 ± 3.740, 63.366 ± 0.840, 66.273 ± 2.603 and 69.936 ± 4.439, in PBMCs exposed to 0, 1, 2 and 6 Gy, respectively. The linear-quadratic dose-response calibration curve for DCA was Y = 0.0017 (±0.0010) + 0.0251 (±0.0142) × D + 0.0342 (±0.0039) × D2 $\boldsymbol{Y}=\mathbf{0.0017}\left(\pm \mathbf{0.0010}\right)+\mathbf{0.0208}\left(\pm \mathbf{0.0218}\right)\times \boldsymbol{D}+\mathbf{0.0350}\left(\pm \mathbf{0.0050}\right)\times{\boldsymbol{D}}^{\mathbf{2}}$. Overall, despite a large variability in the ratio of γ-H2AX/total H2AX among donors, the present study revealed the suitability of using the ratio of γ-H2AX/total H2AX and pATM for biodosimetry. Still, more research with a larger group of subjects is necessary to construct a reliable calibration curve for the ratio of γ-H2AX/total H2AX and pATM levels for biodosimetry.

About this research paper

What this paper is about

In the event of a radiological incident, a fast and accurate biological dosimetry (biodosimetry) method for evaluating people who have been potentially exposed to ionising radiation is crucial. Among the many biodosimetry methods available, the immunodetection of phosphorylated H2AX (γ-H2AX) stands as a promising method to be used in the triage of patients exposed to radiation. Currently, the most common way to measure γ-H2AX levels is through fluorescence microscopy. In this pilot study, we assessed the feasibility of using an enzyme-linked immunosorbent assay (ELISA) for quantifying γ-H2AX for biodosimetry purposes. Moreover, the usefulness of measuring phosphorylated ATM (pATM) levels through ELISA for biodosimetry was also evaluated. Blood samples were obtained from three male donors (38 y) and were irradiated with 60Co (0, 1, 2 and 6 Gy). Peripheral blood mononuclear cells (PBMCs) were isolated and lysed before measuring γ-H2AX, total H2AX protein and pATM using ELISA kits. The dicentric chromosome assay (DCA) using whole blood was also performed for comparison. Data from all donors at each dose were pooled before statistical analysis. The ratio of γ-H2AX/total H2AX and pATM levels increased in a radiation-dose-dependent manner. The average γ-H2AX/total H2AX ratios were 0.816 ± 0.219, 0.830 ± 0.685, 1.276 ± 1.151 and 1.606 ± 1.098, whereas the average levels of pATM were 59.359 ± 3.740, 63.366 ± 0.840, 66.273 ± 2.603 and 69.936 ± 4.439, in PBMCs exposed to 0, 1, 2 and 6 Gy, respectively. The linear-quadratic dose-response calibration curve for DCA was Y = 0.0017 (±0.0010) + 0.0251 (±0.0142) × D + 0.0342 (±0.0039) × D2 $\boldsymbol{Y}=\mathbf{0.0017}\left(\pm \mathbf{0.0010}\right)+\mathbf{0.0208}\left(\pm \mathbf{0.0218}\right)\times \boldsymbol{D}+\mathbf{0.0350}\left(\pm \mathbf{0.0050}\right)\times{\boldsymbol{D}}^{\mathbf{2}}$. Overall, despite a large variability in the ratio of γ-H2AX/total H2AX among donors, the present study revealed the suitability of using the ratio of γ-H2AX/total H2AX and pATM for biodosimetry. Still, more research with a larger group of subjects is necessary to construct a reliable calibration curve for the ratio of γ-H2AX/total H2AX and pATM levels for biodosimetry.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In the event of a radiological incident, a fast and accurate biological dosimetry (biodosimetry) method for evaluating people who have been potentially exposed to ionising radiation is crucial. Among the many biodosimetry methods available, the immunodetection of phosphorylated H2AX (γ-H2AX) stands as a promising method to be used in the triage of patients exposed to radiation. Currently, the most common way to measure γ-H2AX levels is through fluorescence microscopy. In this pilot study, we assessed the feasibility of using an enzyme-linked immunosorbent assay (ELISA) for quantifying γ-H2AX for biodosimetry purposes. Moreover, the usefulness of measuring phosphorylated ATM (pATM) levels through ELISA for biodosimetry was also evaluated. Blood samples were obtained from three male donors (38 y) and were irradiated with 60Co (0, 1, 2 and 6 Gy). Peripheral blood mononuclear cells (PBMCs) were isolated and lysed before measuring γ-H2AX, total H2AX protein and pATM using ELISA kits. The dicentric chromosome assay (DCA) using whole blood was also performed for comparison. Data from all donors at each dose were pooled before statistical analysis. The ratio of γ-H2AX/total H2AX and pATM levels increased in a radiation-dose-dependent manner. The average γ-H2AX/total H2AX ratios were 0.816 ± 0.219, 0.830 ± 0.685, 1.276 ± 1.151 and 1.606 ± 1.098, whereas the average levels of pATM were 59.359 ± 3.740, 63.366 ± 0.840, 66.273 ± 2.603 and 69.936 ± 4.439, in PBMCs exposed to 0, 1, 2 and 6 Gy, respectively. The linear-quadratic dose-response calibration curve for DCA was Y = 0.0017 (±0.0010) + 0.0251 (±0.0142) × D + 0.0342 (±0.0039) × D2 $\boldsymbol{Y}=\mathbf{0.0017}\left(\pm \mathbf{0.0010}\right)+\mathbf{0.0208}\left(\pm \mathbf{0.0218}\right)\times \boldsymbol{D}+\mathbf{0.0350}\left(\pm \mathbf{0.0050}\right)\times{\boldsymbol{D}}^{\mathbf{2}}$. Overall, despite a large variability in the ratio of γ-H2AX/total H2AX among donors, the present study revealed the suitability of using the ratio of γ-H2AX/total H2AX and pATM for biodosimetry. Still, more research with a larger group of subjects is necessary to construct a reliable calibration curve for the ratio of γ-H2AX/total H2AX and pATM levels for biodosimetry.

Key concepts: Biodosimetry, Ionizing radiation, Dicentric chromosome, Dosimetry, Nuclear medicine, Medicine, Peripheral blood mononuclear cell, Biology

Related papers

Back to paper searchBrowse research topicsOriginal source
γ-H2AX and phospho-ATM enzyme-linked immunosorbent assays as biodosimetry methods for radiation exposure assessment: a pilot study — Research Paper | ScholarLens