2023•Fusion Science & TechnologyRequires access

New Achievements of H 2 -HD-D 2 Isotopic Separation with the Cryogenic Distillation Experimental Stand from ICSI Cryogenic Laboratory

Sebastian Brad, Mihai Vijulie, Alin Lazăr, Claudia Bogdan, Oleksandr Sirosh, Cătălin Brill, Aleksandr Grafov, Anișoara Oubraham, Alina Niculescu, Gheorghe Bulubașa

Open publisher page 5 citations

Abstract

In the design process of a cryogenic distillation plant for the separation of hydrogen isotopes, two main objectives, often impossible to achieve simultaneously, are taken into account: a high separation factor for different mixtures and isotope concentrations and the reduction of design, manufacturing, and operating costs with increased efficiency and safety. All this should result from the use of a method for calculating the separation efficiency, a method that will generate a conceptual design that must form the basis of the final technical design. Unfortunately, most design methods treat these plants as chemical plants, although in the case of cryogenic plants, it is not possible to readjust the new process operating parameters quickly and with great precision so that the separation efficiency and performance are not affected. There are three causes affecting the separation performance of cryogenic distillation plants, namely, nonideality of the cryogenic process, imperfection of heat exchangers, and heat losses. This paper presents our proposed solutions for increasing the efficiency of the cryogenic distillation process and discusses solutions tested in experimental campaigns with the cryogenic distillation stand developed in the Cryogenic Laboratory at ICSI Rm. Vâlcea.

About this research paper

What this paper is about

In the design process of a cryogenic distillation plant for the separation of hydrogen isotopes, two main objectives, often impossible to achieve simultaneously, are taken into account: a high separation factor for different mixtures and isotope concentrations and the reduction of design, manufacturing, and operating costs with increased efficiency and safety. All this should result from the use of a method for calculating the separation efficiency, a method that will generate a conceptual design that must form the basis of the final technical design. Unfortunately, most design methods treat these plants as chemical plants, although in the case of cryogenic plants, it is not possible to readjust the new process operating parameters quickly and with great precision so that the separation efficiency and performance are not affected. There are three causes affecting the separation performance of cryogenic distillation plants, namely, nonideality of the cryogenic process, imperfection of heat exchangers, and heat losses. This paper presents our proposed solutions for increasing the efficiency of the cryogenic distillation process and discusses solutions tested in experimental campaigns with the cryogenic distillation stand developed in the Cryogenic Laboratory at ICSI Rm. Vâlcea.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In the design process of a cryogenic distillation plant for the separation of hydrogen isotopes, two main objectives, often impossible to achieve simultaneously, are taken into account: a high separation factor for different mixtures and isotope concentrations and the reduction of design, manufacturing, and operating costs with increased efficiency and safety. All this should result from the use of a method for calculating the separation efficiency, a method that will generate a conceptual design that must form the basis of the final technical design. Unfortunately, most design methods treat these plants as chemical plants, although in the case of cryogenic plants, it is not possible to readjust the new process operating parameters quickly and with great precision so that the separation efficiency and performance are not affected. There are three causes affecting the separation performance of cryogenic distillation plants, namely, nonideality of the cryogenic process, imperfection of heat exchangers, and heat losses. This paper presents our proposed solutions for increasing the efficiency of the cryogenic distillation process and discusses solutions tested in experimental campaigns with the cryogenic distillation stand developed in the Cryogenic Laboratory at ICSI Rm. Vâlcea.

Key concepts: Distillation, Cryogenics, Air separation, Process engineering, Heat exchanger, Isotope separation, Separation (statistics), Separation process