2023Scientific ReportsOpen access

Microsurgical robotic system enables the performance of microvascular anastomoses: a randomized in vivo preclinical trial

Gerardo Malzone, Giulio Menichini, Marco Innocenti, Alberto Ballestín

Open full text 57 citations

Abstract

Technical advances in microsurgery have enabled complex oncological reconstructions by performing free tissue transfers, nerve and lymphatic reconstructions. However, the manual abilities required to perform microsurgery can be affected by human fatigue and physiological tremor resulting in tissue damage and compromised outcomes. Robotic assistance has the potential to overcome issues of manual microsurgery by improving clinical value and anastomoses' outcomes. The Symani Surgical System, a robotic platform designed for microsurgery, was used in this in-vivo preclinical study using a rat animal model. The tests included anastomoses on veins and arteries performed by microsurgeons manually and robotically, with the latter approach using Symani. The anastomoses were assessed for patency, histopathology, and execution time. Patency results confirmed that the robotic and manual techniques for venous and arterial anastomoses were equivalent after anastomosis, however, the time to perform the anastomosis was longer with the use of the robot (p < 0.0001). Histological analysis showed less total average host reaction score at the anastomotic site in robotic anastomosis for both veins and arteries. This study demonstrates the equivalence of vessel patency after microsurgical anastomoses with the robotic system and with manual technique. Furthermore, robotic anastomosis has proven to be slightly superior to manual anastomosis in terms of decreased tissue damage, as shown by histological analysis.

Open-access reader

About this research paper

What this paper is about

Technical advances in microsurgery have enabled complex oncological reconstructions by performing free tissue transfers, nerve and lymphatic reconstructions. However, the manual abilities required to perform microsurgery can be affected by human fatigue and physiological tremor resulting in tissue damage and compromised outcomes. Robotic assistance has the potential to overcome issues of manual microsurgery by improving clinical value and anastomoses' outcomes. The Symani Surgical System, a robotic platform designed for microsurgery, was used in this in-vivo preclinical study using a rat animal model. The tests included anastomoses on veins and arteries performed by microsurgeons manually and robotically, with the latter approach using Symani. The anastomoses were assessed for patency, histopathology, and execution time. Patency results confirmed that the robotic and manual techniques for venous and arterial anastomoses were equivalent after anastomosis, however, the time to perform the anastomosis was longer with the use of the robot (p < 0.0001). Histological analysis showed less total average host reaction score at the anastomotic site in robotic anastomosis for both veins and arteries. This study demonstrates the equivalence of vessel patency after microsurgical anastomoses with the robotic system and with manual technique. Furthermore, robotic anastomosis has proven to be slightly superior to manual anastomosis in terms of decreased tissue damage, as shown by histological analysis.

Why it matters

OpenAlex reports 57 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Technical advances in microsurgery have enabled complex oncological reconstructions by performing free tissue transfers, nerve and lymphatic reconstructions. However, the manual abilities required to perform microsurgery can be affected by human fatigue and physiological tremor resulting in tissue damage and compromised outcomes. Robotic assistance has the potential to overcome issues of manual microsurgery by improving clinical value and anastomoses' outcomes. The Symani Surgical System, a robotic platform designed for microsurgery, was used in this in-vivo preclinical study using a rat animal model. The tests included anastomoses on veins and arteries performed by microsurgeons manually and robotically, with the latter approach using Symani. The anastomoses were assessed for patency, histopathology, and execution time. Patency results confirmed that the robotic and manual techniques for venous and arterial anastomoses were equivalent after anastomosis, however, the time to perform the anastomosis was longer with the use of the robot (p < 0.0001). Histological analysis showed less total average host reaction score at the anastomotic site in robotic anastomosis for both veins and arteries. This study demonstrates the equivalence of vessel patency after microsurgical anastomoses with the robotic system and with manual technique. Furthermore, robotic anastomosis has proven to be slightly superior to manual anastomosis in terms of decreased tissue damage, as shown by histological analysis.

Key concepts: Microsurgery, Anastomosis, Medicine, In vivo, Surgery, Biomedical engineering, Biology, Biotechnology

Related papers

Back to paper searchBrowse research topicsOriginal source
Microsurgical robotic system enables the performance of microvascular anastomoses: a randomized in vivo preclinical trial — Research Paper | ScholarLens