Recent Upgrades of the Gas Handling System for the Cryogenic Stopping Cell of the FRS Ion Catcher

Ali Mollaebrahimi, Daler Amanbayev, Andrés, S. Ayet San, Sönke Beck, J. Bergmann, T. Dickel, Hans Geissel, C. Hornung, N. Kalantar-Nayestanaki, Gabriella Kripkó-Koncz, Ivan Miskun, D. Nichita, W. R. Plaß, I. Pohjalainen, Christoph Scheidenberger, Goran Stanić, Alexandru N. State, Jian-Wei Zhao

Open full text 0 citations

Abstract

In this paper, the major upgrades and technical improvements of the buffer gas handling system for the cryogenic stopping cell of the FRS Ion Catcher at GSI/FAIR (in Darmstadt, Germany) are described. The upgrades include implementation of new gas lines and gas purifiers to achieve a higher buffer gas cleanliness for a more efficient extraction of reactive ions as well as suppression of the molecular background ionized in the stopping cell. Furthermore, additional techniques have been implemented for improved monitoring and quantification of the purity of the helium buffer gas.

About this research paper

What this paper is about

In this paper, the major upgrades and technical improvements of the buffer gas handling system for the cryogenic stopping cell of the FRS Ion Catcher at GSI/FAIR (in Darmstadt, Germany) are described. The upgrades include implementation of new gas lines and gas purifiers to achieve a higher buffer gas cleanliness for a more efficient extraction of reactive ions as well as suppression of the molecular background ionized in the stopping cell. Furthermore, additional techniques have been implemented for improved monitoring and quantification of the purity of the helium buffer gas.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this paper, the major upgrades and technical improvements of the buffer gas handling system for the cryogenic stopping cell of the FRS Ion Catcher at GSI/FAIR (in Darmstadt, Germany) are described. The upgrades include implementation of new gas lines and gas purifiers to achieve a higher buffer gas cleanliness for a more efficient extraction of reactive ions as well as suppression of the molecular background ionized in the stopping cell. Furthermore, additional techniques have been implemented for improved monitoring and quantification of the purity of the helium buffer gas.

Key concepts: Buffer gas, Helium gas, Helium, Nuclear engineering, Ion, Chemistry, Physics, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Recent Upgrades of the Gas Handling System for the Cryogenic Stopping Cell of the FRS Ion Catcher — Research Paper | ScholarLens