2023Unpublished venueRequires access

Extended Embedded Depth Using Cascaded Resonators Near-field WPT System with High Efficiency for Biomedical Implants

Mohamed Aboualalaa, Ramesh K. Pokharel, Takana Kaho

Open publisher page 7 citations

Abstract

A novel multiple cascaded resonators wireless power transfer (WPT) design is proposed to provide an extended implanted depth for biomedical implants. Symmetrical four cascaded resonators are utilized in Tx/Rx to obtain high power transfer efficiency (PTE); each resonator consists of two concentric rectangular loops. KQ-product is calculated for a single resonator and compared with the four resonators WPT; four cascaded resonators achieve higher KQ-product value and produce a maximum measured PTE of 89.5% at a transfer distance of 20 mm. Then, the proposed WPT is tested with human tissue to provide a measured PTE of 76% and 63% at a transfer distance of 15 and 20mm, respectively. Specific absorption rate (SAR) is calculated to estimate the maximum operating power of the source and receiver that guarantees working within the safety standard levels of RF exposure.

About this research paper

What this paper is about

A novel multiple cascaded resonators wireless power transfer (WPT) design is proposed to provide an extended implanted depth for biomedical implants. Symmetrical four cascaded resonators are utilized in Tx/Rx to obtain high power transfer efficiency (PTE); each resonator consists of two concentric rectangular loops. KQ-product is calculated for a single resonator and compared with the four resonators WPT; four cascaded resonators achieve higher KQ-product value and produce a maximum measured PTE of 89.5% at a transfer distance of 20 mm. Then, the proposed WPT is tested with human tissue to provide a measured PTE of 76% and 63% at a transfer distance of 15 and 20mm, respectively. Specific absorption rate (SAR) is calculated to estimate the maximum operating power of the source and receiver that guarantees working within the safety standard levels of RF exposure.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A novel multiple cascaded resonators wireless power transfer (WPT) design is proposed to provide an extended implanted depth for biomedical implants. Symmetrical four cascaded resonators are utilized in Tx/Rx to obtain high power transfer efficiency (PTE); each resonator consists of two concentric rectangular loops. KQ-product is calculated for a single resonator and compared with the four resonators WPT; four cascaded resonators achieve higher KQ-product value and produce a maximum measured PTE of 89.5% at a transfer distance of 20 mm. Then, the proposed WPT is tested with human tissue to provide a measured PTE of 76% and 63% at a transfer distance of 15 and 20mm, respectively. Specific absorption rate (SAR) is calculated to estimate the maximum operating power of the source and receiver that guarantees working within the safety standard levels of RF exposure.

Key concepts: Resonator, Wireless power transfer, Specific absorption rate, Materials science, Maximum power transfer theorem, Acoustics, Power (physics), Optoelectronics

Related papers

Back to paper searchBrowse research topicsOriginal source
Extended Embedded Depth Using Cascaded Resonators Near-field WPT System with High Efficiency for Biomedical Implants — Research Paper | ScholarLens