2023Operative DentistryRequires access

Effect of the Absence of HEMA on the Bonding Properties of Universal Adhesive Systems Containing 10-MDP: An In Vitro Study

Michel Wendlinger, Alejandra Núñez, PHA Moreira, TS Carneiro, GD Cochinski, F Siqueira, AFM Cardenas, Alessandro Dourado Loguércio

Open publisher page 23 citations

Abstract

OBJECTIVES: To evaluate the absence of 2-hydroxyethyl methacrylate (HEMA) on the adhesive properties with enamel and dentin of universal adhesive systems containing 10-methacryloyloxydecyl dihydrogen phosphate (MDP). METHODS AND MATERIALS: One hundred and twelve caries-free third molars were used to test adhesion to dentin (n=64) and enamel (n=48). For each substrate, teeth were divided into eight experimental groups: four different adhesives each using two adhesive strategies. The adhesives used were: (1) Scotchbond Universal (SBU, 3M Oral Care, St Paul, MN, USA) as a HEMA-containing universal adhesive; (2) Gluma Bond Universal (GBU, Kulzer, Hanau, Germany); (3) Solare Universal Bond (SUB, GC, Tokyo, Japan); and (4) Zipbond Universal (ZIP, SDI, Victoria, Australia) as HEMA-free universal adhesives. The adhesive strategies used were etch-and-rinse (ER) and self-etch (SE). For dentin tests, the occlusal third of the crown of all teeth was removed and an adhesive protocol was applied. After completing the restoration, specimens were sectioned into bonded sticks (0.8 mm 2) and tested for microtensile bond strength (μTBS), in situ degree of conversion (DC), and nanoleakage (NL) by scanning electron microscopy. For enamel tests, teeth were sectioned into four parts (buccal, lingual, and proximal), and an adhesive protocol was applied. After completing the restoration, the specimens were tested for their microshear bond strength (μSBS). For in situ degree of conversion (DC) and nanoleakage (NL) evaluation of enamel, the specimens were sectioned in slices to be evaluated. The data for each substrate were subjected to two-way ANOVA and Tukey's test (α=0.05) for each property evaluated. RESULTS: The SBU and ZIP adhesives showed the highest μSBS, and DC (dentin and enamel) and lower NL (dentin) values compared to GBU and SUB (p=0.001). However, SBU showed better results in terms of μTBS and μSBS (SE strategy), and DC (dentin and enamel) than ZIP. Strategy ER presented higher values of μTBS and μSBS when compared to strategy SE (p=0.001), except for SBU. CONCLUSION: The effect of the absence of HEMA in commercial universal adhesive systems on enamel and dentin adhesive properties appears to be material-dependent.

About this research paper

What this paper is about

OBJECTIVES: To evaluate the absence of 2-hydroxyethyl methacrylate (HEMA) on the adhesive properties with enamel and dentin of universal adhesive systems containing 10-methacryloyloxydecyl dihydrogen phosphate (MDP). METHODS AND MATERIALS: One hundred and twelve caries-free third molars were used to test adhesion to dentin (n=64) and enamel (n=48). For each substrate, teeth were divided into eight experimental groups: four different adhesives each using two adhesive strategies. The adhesives used were: (1) Scotchbond Universal (SBU, 3M Oral Care, St Paul, MN, USA) as a HEMA-containing universal adhesive; (2) Gluma Bond Universal (GBU, Kulzer, Hanau, Germany); (3) Solare Universal Bond (SUB, GC, Tokyo, Japan); and (4) Zipbond Universal (ZIP, SDI, Victoria, Australia) as HEMA-free universal adhesives. The adhesive strategies used were etch-and-rinse (ER) and self-etch (SE). For dentin tests, the occlusal third of the crown of all teeth was removed and an adhesive protocol was applied. After completing the restoration, specimens were sectioned into bonded sticks (0.8 mm 2) and tested for microtensile bond strength (μTBS), in situ degree of conversion (DC), and nanoleakage (NL) by scanning electron microscopy. For enamel tests, teeth were sectioned into four parts (buccal, lingual, and proximal), and an adhesive protocol was applied. After completing the restoration, the specimens were tested for their microshear bond strength (μSBS). For in situ degree of conversion (DC) and nanoleakage (NL) evaluation of enamel, the specimens were sectioned in slices to be evaluated. The data for each substrate were subjected to two-way ANOVA and Tukey's test (α=0.05) for each property evaluated. RESULTS: The SBU and ZIP adhesives showed the highest μSBS, and DC (dentin and enamel) and lower NL (dentin) values compared to GBU and SUB (p=0.001). However, SBU showed better results in terms of μTBS and μSBS (SE strategy), and DC (dentin and enamel) than ZIP. Strategy ER presented higher values of μTBS and μSBS when compared to strategy SE (p=0.001), except for SBU. CONCLUSION: The effect of the absence of HEMA in commercial universal adhesive systems on enamel and dentin adhesive properties appears to be material-dependent.

Why it matters

OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVES: To evaluate the absence of 2-hydroxyethyl methacrylate (HEMA) on the adhesive properties with enamel and dentin of universal adhesive systems containing 10-methacryloyloxydecyl dihydrogen phosphate (MDP). METHODS AND MATERIALS: One hundred and twelve caries-free third molars were used to test adhesion to dentin (n=64) and enamel (n=48). For each substrate, teeth were divided into eight experimental groups: four different adhesives each using two adhesive strategies. The adhesives used were: (1) Scotchbond Universal (SBU, 3M Oral Care, St Paul, MN, USA) as a HEMA-containing universal adhesive; (2) Gluma Bond Universal (GBU, Kulzer, Hanau, Germany); (3) Solare Universal Bond (SUB, GC, Tokyo, Japan); and (4) Zipbond Universal (ZIP, SDI, Victoria, Australia) as HEMA-free universal adhesives. The adhesive strategies used were etch-and-rinse (ER) and self-etch (SE). For dentin tests, the occlusal third of the crown of all teeth was removed and an adhesive protocol was applied. After completing the restoration, specimens were sectioned into bonded sticks (0.8 mm 2) and tested for microtensile bond strength (μTBS), in situ degree of conversion (DC), and nanoleakage (NL) by scanning electron microscopy. For enamel tests, teeth were sectioned into four parts (buccal, lingual, and proximal), and an adhesive protocol was applied. After completing the restoration, the specimens were tested for their microshear bond strength (μSBS). For in situ degree of conversion (DC) and nanoleakage (NL) evaluation of enamel, the specimens were sectioned in slices to be evaluated. The data for each substrate were subjected to two-way ANOVA and Tukey's test (α=0.05) for each property evaluated. RESULTS: The SBU and ZIP adhesives showed the highest μSBS, and DC (dentin and enamel) and lower NL (dentin) values compared to GBU and SUB (p=0.001). However, SBU showed better results in terms of μTBS and μSBS (SE strategy), and DC (dentin and enamel) than ZIP. Strategy ER presented higher values of μTBS and μSBS when compared to strategy SE (p=0.001), except for SBU. CONCLUSION: The effect of the absence of HEMA in commercial universal adhesive systems on enamel and dentin adhesive properties appears to be material-dependent.

Key concepts: Adhesive, Enamel paint, Dentin, Molar, Materials science, Bond strength, Universal testing machine, Methacrylate

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of the Absence of HEMA on the Bonding Properties of Universal Adhesive Systems Containing 10-MDP: An In Vitro Study — Research Paper | ScholarLens