2023Japan Architectural ReviewOpen access

Exploring the impact of opening ratio on indoor thermal environment: A study on natural ventilation design

Kei SHIMONOSONO, Yuji SASAKI, Kimiko KOHRI

Open full text 2 citations

Abstract

Abstract The utilization of natural ventilation to reduce thermal load and enhance thermal comfort in buildings is on the rise. Furthermore, in light of the COVID‐19 impact, natural ventilation is gaining prominence as an increasingly vital technology. However, it is crucial to address potential challenges associated with natural ventilation, particularly its impact on the indoor thermal environment. This study aimed to examine and offer insights into natural ventilation design and operational strategies for office buildings. We initially summarized the criteria and effective opening area of natural ventilation openings (αAi) in Japanese naturally ventilated buildings. Among the 37 investigated office buildings, we found a positive correlation between the natural ventilation room area and the αAi. Approximately, 25 buildings maintained a ratio of αAi to the natural ventilation room area ranging from 0.1%–0.5%. Additionally, we conducted measurements of the indoor thermal environment, focusing on the opening ratio of natural ventilation openings. The difference of indoor and outdoor temperature showed a strong negative correlation with the opening ratio, while wind direction and global solar radiation exhibited significant correlations as well. These research findings provide valuable insights for future natural ventilation designs and the incorporation of opening ratio concepts into operational methods.

Open-access reader

About this research paper

What this paper is about

Abstract The utilization of natural ventilation to reduce thermal load and enhance thermal comfort in buildings is on the rise. Furthermore, in light of the COVID‐19 impact, natural ventilation is gaining prominence as an increasingly vital technology. However, it is crucial to address potential challenges associated with natural ventilation, particularly its impact on the indoor thermal environment. This study aimed to examine and offer insights into natural ventilation design and operational strategies for office buildings. We initially summarized the criteria and effective opening area of natural ventilation openings (αAi) in Japanese naturally ventilated buildings. Among the 37 investigated office buildings, we found a positive correlation between the natural ventilation room area and the αAi. Approximately, 25 buildings maintained a ratio of αAi to the natural ventilation room area ranging from 0.1%–0.5%. Additionally, we conducted measurements of the indoor thermal environment, focusing on the opening ratio of natural ventilation openings. The difference of indoor and outdoor temperature showed a strong negative correlation with the opening ratio, while wind direction and global solar radiation exhibited significant correlations as well. These research findings provide valuable insights for future natural ventilation designs and the incorporation of opening ratio concepts into operational methods.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract The utilization of natural ventilation to reduce thermal load and enhance thermal comfort in buildings is on the rise. Furthermore, in light of the COVID‐19 impact, natural ventilation is gaining prominence as an increasingly vital technology. However, it is crucial to address potential challenges associated with natural ventilation, particularly its impact on the indoor thermal environment. This study aimed to examine and offer insights into natural ventilation design and operational strategies for office buildings. We initially summarized the criteria and effective opening area of natural ventilation openings (αAi) in Japanese naturally ventilated buildings. Among the 37 investigated office buildings, we found a positive correlation between the natural ventilation room area and the αAi. Approximately, 25 buildings maintained a ratio of αAi to the natural ventilation room area ranging from 0.1%–0.5%. Additionally, we conducted measurements of the indoor thermal environment, focusing on the opening ratio of natural ventilation openings. The difference of indoor and outdoor temperature showed a strong negative correlation with the opening ratio, while wind direction and global solar radiation exhibited significant correlations as well. These research findings provide valuable insights for future natural ventilation designs and the incorporation of opening ratio concepts into operational methods.

Key concepts: Natural ventilation, Ventilation (architecture), Environmental science, Natural (archaeology), Thermal comfort, Architectural engineering, Thermal, Marine engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Exploring the impact of opening ratio on indoor thermal environment: A study on natural ventilation design — Research Paper | ScholarLens