An integrated calibration method for the cross-shaped magnetic gradiometer
Jianfei Ma, Haifeng Tan, Zhiqiang Wang, Mingquan Yang
Abstract
Open-access reader
Jianfei Ma, Haifeng Tan, Zhiqiang Wang, Mingquan Yang
Abstract
Open-access reader
The measurement accuracy of a magnetic gradiometer relies on magnetometer consistency, measurement accuracy, and assembly technology. The traditional methods calibrate measurement error, misalignment error, and the interference magnetic field independently. However, after a long time of work, the calibration parameters will inevitably change. Furthermore, it will waste a lot of manpower and material resources if the magnetic gradiometer is disassembled and calibrated step by step. Given the above problems, a novel attitude-independent calibration algorithm using a limited number of measurement points is proposed, which can effectively overcome the measurement distortion of the magnetic gradiometer and does not rely on a reference magnetometer. For the cross-shaped magnetic gradiometer, the simulation results show that the error after integrated calibration is reduced to less than 8% of the error before calibration. The test results suggest that the magnetic gradient results before calibration are even up to 1.5 µT/m, whereas the magnetic gradient results after the integrated calibration are less than 100 nT/m.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The measurement accuracy of a magnetic gradiometer relies on magnetometer consistency, measurement accuracy, and assembly technology. The traditional methods calibrate measurement error, misalignment error, and the interference magnetic field independently. However, after a long time of work, the calibration parameters will inevitably change. Furthermore, it will waste a lot of manpower and material resources if the magnetic gradiometer is disassembled and calibrated step by step. Given the above problems, a novel attitude-independent calibration algorithm using a limited number of measurement points is proposed, which can effectively overcome the measurement distortion of the magnetic gradiometer and does not rely on a reference magnetometer. For the cross-shaped magnetic gradiometer, the simulation results show that the error after integrated calibration is reduced to less than 8% of the error before calibration. The test results suggest that the magnetic gradient results before calibration are even up to 1.5 µT/m, whereas the magnetic gradient results after the integrated calibration are less than 100 nT/m.
Key concepts: Gradiometer, Calibration, Magnetometer, Distortion (music), Magnetic field, Accuracy and precision, Observational error, Consistency (knowledge bases)