2023•AIP AdvancesOpen access

An integrated calibration method for the cross-shaped magnetic gradiometer

Jianfei Ma, Haifeng Tan, Zhiqiang Wang, Mingquan Yang

Open full text 0 citations

Abstract

The measurement accuracy of a magnetic gradiometer relies on magnetometer consistency, measurement accuracy, and assembly technology. The traditional methods calibrate measurement error, misalignment error, and the interference magnetic field independently. However, after a long time of work, the calibration parameters will inevitably change. Furthermore, it will waste a lot of manpower and material resources if the magnetic gradiometer is disassembled and calibrated step by step. Given the above problems, a novel attitude-independent calibration algorithm using a limited number of measurement points is proposed, which can effectively overcome the measurement distortion of the magnetic gradiometer and does not rely on a reference magnetometer. For the cross-shaped magnetic gradiometer, the simulation results show that the error after integrated calibration is reduced to less than 8% of the error before calibration. The test results suggest that the magnetic gradient results before calibration are even up to 1.5 µT/m, whereas the magnetic gradient results after the integrated calibration are less than 100 nT/m.

Open-access reader

About this research paper

What this paper is about

The measurement accuracy of a magnetic gradiometer relies on magnetometer consistency, measurement accuracy, and assembly technology. The traditional methods calibrate measurement error, misalignment error, and the interference magnetic field independently. However, after a long time of work, the calibration parameters will inevitably change. Furthermore, it will waste a lot of manpower and material resources if the magnetic gradiometer is disassembled and calibrated step by step. Given the above problems, a novel attitude-independent calibration algorithm using a limited number of measurement points is proposed, which can effectively overcome the measurement distortion of the magnetic gradiometer and does not rely on a reference magnetometer. For the cross-shaped magnetic gradiometer, the simulation results show that the error after integrated calibration is reduced to less than 8% of the error before calibration. The test results suggest that the magnetic gradient results before calibration are even up to 1.5 µT/m, whereas the magnetic gradient results after the integrated calibration are less than 100 nT/m.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The measurement accuracy of a magnetic gradiometer relies on magnetometer consistency, measurement accuracy, and assembly technology. The traditional methods calibrate measurement error, misalignment error, and the interference magnetic field independently. However, after a long time of work, the calibration parameters will inevitably change. Furthermore, it will waste a lot of manpower and material resources if the magnetic gradiometer is disassembled and calibrated step by step. Given the above problems, a novel attitude-independent calibration algorithm using a limited number of measurement points is proposed, which can effectively overcome the measurement distortion of the magnetic gradiometer and does not rely on a reference magnetometer. For the cross-shaped magnetic gradiometer, the simulation results show that the error after integrated calibration is reduced to less than 8% of the error before calibration. The test results suggest that the magnetic gradient results before calibration are even up to 1.5 µT/m, whereas the magnetic gradient results after the integrated calibration are less than 100 nT/m.

Key concepts: Gradiometer, Calibration, Magnetometer, Distortion (music), Magnetic field, Accuracy and precision, Observational error, Consistency (knowledge bases)

Related papers

Back to paper searchBrowse research topicsOriginal source
An integrated calibration method for the cross-shaped magnetic gradiometer — Research Paper | ScholarLens