2013DOAJ (DOAJ: Directory of Open Access Journals)Open access

The Sealing Ability of Different Thickness of Orthograde Apical Plug of Mineral Trioxide Aggregate in Comparison with Gutta-Percha and Sealer AH26

Alireza Mohamadi, Mohamad Hosein Nekofar, Pegah Saraf, Mohamad Saieed Sheykhrezaie

Open full text 0 citations

Abstract

Background and Aims: The purpose of this study was to evaluate the sealing ability of different thicknesses of orthograde MTA plugs in comparison with 5 mm gutta-percha.Materials and Methods: Fifty extracted single rooted human teeth were collected. After root canal preparation,the samples were randomly divided into 4 experimental (n=10) and two control groups (n=5). In group 1, the apical 5 mm of the canals were obturated using laterally condensed gutta-percha and sealer AH26. Groups 2, 3and 4 received 2, 3 and 4-mm thick orthograde MTA plug,respectively. Thereafter, the coronal portion of specimens was exposed to the microbial solution containing streptococcus sanguis and the root tips were placed in phenol red lactose broth. The color changes were observed within 60 days. The data were analyzed with Fisher exact test.Results: The leakage was found in all samples (100%) in group 1 and 72.7%, 30.8% and 50% of the samples in groups 2, 3 and 4, respectively. Significant difference was found between 3 mm thickness of MTA plug and gutta percha and sealer (P=0.02).Conclusion: According to the findings, it seems that 3 mm thickness of orthograde MTA plug had better sealing ability than the other thicknesses of MTA plug as well as the 5 mm of gutta-percha.

About this research paper

What this paper is about

Background and Aims: The purpose of this study was to evaluate the sealing ability of different thicknesses of orthograde MTA plugs in comparison with 5 mm gutta-percha.Materials and Methods: Fifty extracted single rooted human teeth were collected. After root canal preparation,the samples were randomly divided into 4 experimental (n=10) and two control groups (n=5). In group 1, the apical 5 mm of the canals were obturated using laterally condensed gutta-percha and sealer AH26. Groups 2, 3and 4 received 2, 3 and 4-mm thick orthograde MTA plug,respectively. Thereafter, the coronal portion of specimens was exposed to the microbial solution containing streptococcus sanguis and the root tips were placed in phenol red lactose broth. The color changes were observed within 60 days. The data were analyzed with Fisher exact test.Results: The leakage was found in all samples (100%) in group 1 and 72.7%, 30.8% and 50% of the samples in groups 2, 3 and 4, respectively. Significant difference was found between 3 mm thickness of MTA plug and gutta percha and sealer (P=0.02).Conclusion: According to the findings, it seems that 3 mm thickness of orthograde MTA plug had better sealing ability than the other thicknesses of MTA plug as well as the 5 mm of gutta-percha.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background and Aims: The purpose of this study was to evaluate the sealing ability of different thicknesses of orthograde MTA plugs in comparison with 5 mm gutta-percha.Materials and Methods: Fifty extracted single rooted human teeth were collected. After root canal preparation,the samples were randomly divided into 4 experimental (n=10) and two control groups (n=5). In group 1, the apical 5 mm of the canals were obturated using laterally condensed gutta-percha and sealer AH26. Groups 2, 3and 4 received 2, 3 and 4-mm thick orthograde MTA plug,respectively. Thereafter, the coronal portion of specimens was exposed to the microbial solution containing streptococcus sanguis and the root tips were placed in phenol red lactose broth. The color changes were observed within 60 days. The data were analyzed with Fisher exact test.Results: The leakage was found in all samples (100%) in group 1 and 72.7%, 30.8% and 50% of the samples in groups 2, 3 and 4, respectively. Significant difference was found between 3 mm thickness of MTA plug and gutta percha and sealer (P=0.02).Conclusion: According to the findings, it seems that 3 mm thickness of orthograde MTA plug had better sealing ability than the other thicknesses of MTA plug as well as the 5 mm of gutta-percha.

Key concepts: Mineral trioxide aggregate, Gutta-percha, Spark plug, Aggregate (composite), Materials science, Chemistry, Dentistry, Composite material

Related papers

Back to paper searchBrowse research topicsOriginal source
The Sealing Ability of Different Thickness of Orthograde Apical Plug of Mineral Trioxide Aggregate in Comparison with Gutta-Percha and Sealer AH26 — Research Paper | ScholarLens