2023•Brazilian Journal of Radiation SciencesOpen access

3D modeling of bolus for producing by prototyping and use in radiation therapy

Larissa Cristina Silva dos Santos, José Wilson Vieira, Fernando Roberto de Andrade Lima, Alex Cristóvão Holanda de Oliveira

Open full text 0 citations

Abstract

Due to its vast number of occurrences, cancer has caused an economic impact on the public and supplementary health care sectors. It is estimated that more than 50% of patients diagnosed with malignant neoplasms need radiotherapy at some stage of their treatment, most of them treated with photon and/or electron beams. Due to the build-up effect (increase in dose in the matter from deposition on the surface to a point of maximum dose) caused by the interaction of photon beams with the irradiated tissue, bolus is often used in routine radiotherapy sectors to superficialize the point of maximum dose in the treatment region. The human body has complex surfaces that are often treatment regions in radiotherapy, but commercial bolus with a standard shape and length do not adapt perfectly to these surfaces. When this happens, air gaps may appear in the region, causing differences between the dose defined in radiotherapy planning and the dose delivered during treatment. In order to eliminate these air gaps and possible dose distribution errors, two methodologies for individualized bolus construction were proposed. In both cases, computed tomography images of the Alderson Rando male anthropomorphic phantom were used as a reference of the anatomy of a human body. From these images, one bolus model was constructed in the 3D modeling software 3ds Max by creating a polygonal mesh, while the other bolus model was constructed in the image computing software 3D Slicer, using segmentation tools. The software Creality Slicer 1.2.3. prepared the files for 3D printing. The prints of the files were made on polylactic acid filament on the Tevo Tarantula Pro printer. The bolus construction methodology using the software 3ds Max showed better results, as a greater contact area between the bolus and the phantom was observed when testing the fit of the printed bolus to the physical phantom. The 3D files of the virtual bolus will be available for future computer simulations. The printed bolus could be used in dosimetry with linear accelerators.

Open-access reader

About this research paper

What this paper is about

Due to its vast number of occurrences, cancer has caused an economic impact on the public and supplementary health care sectors. It is estimated that more than 50% of patients diagnosed with malignant neoplasms need radiotherapy at some stage of their treatment, most of them treated with photon and/or electron beams. Due to the build-up effect (increase in dose in the matter from deposition on the surface to a point of maximum dose) caused by the interaction of photon beams with the irradiated tissue, bolus is often used in routine radiotherapy sectors to superficialize the point of maximum dose in the treatment region. The human body has complex surfaces that are often treatment regions in radiotherapy, but commercial bolus with a standard shape and length do not adapt perfectly to these surfaces. When this happens, air gaps may appear in the region, causing differences between the dose defined in radiotherapy planning and the dose delivered during treatment. In order to eliminate these air gaps and possible dose distribution errors, two methodologies for individualized bolus construction were proposed. In both cases, computed tomography images of the Alderson Rando male anthropomorphic phantom were used as a reference of the anatomy of a human body. From these images, one bolus model was constructed in the 3D modeling software 3ds Max by creating a polygonal mesh, while the other bolus model was constructed in the image computing software 3D Slicer, using segmentation tools. The software Creality Slicer 1.2.3. prepared the files for 3D printing. The prints of the files were made on polylactic acid filament on the Tevo Tarantula Pro printer. The bolus construction methodology using the software 3ds Max showed better results, as a greater contact area between the bolus and the phantom was observed when testing the fit of the printed bolus to the physical phantom. The 3D files of the virtual bolus will be available for future computer simulations. The printed bolus could be used in dosimetry with linear accelerators.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Due to its vast number of occurrences, cancer has caused an economic impact on the public and supplementary health care sectors. It is estimated that more than 50% of patients diagnosed with malignant neoplasms need radiotherapy at some stage of their treatment, most of them treated with photon and/or electron beams. Due to the build-up effect (increase in dose in the matter from deposition on the surface to a point of maximum dose) caused by the interaction of photon beams with the irradiated tissue, bolus is often used in routine radiotherapy sectors to superficialize the point of maximum dose in the treatment region. The human body has complex surfaces that are often treatment regions in radiotherapy, but commercial bolus with a standard shape and length do not adapt perfectly to these surfaces. When this happens, air gaps may appear in the region, causing differences between the dose defined in radiotherapy planning and the dose delivered during treatment. In order to eliminate these air gaps and possible dose distribution errors, two methodologies for individualized bolus construction were proposed. In both cases, computed tomography images of the Alderson Rando male anthropomorphic phantom were used as a reference of the anatomy of a human body. From these images, one bolus model was constructed in the 3D modeling software 3ds Max by creating a polygonal mesh, while the other bolus model was constructed in the image computing software 3D Slicer, using segmentation tools. The software Creality Slicer 1.2.3. prepared the files for 3D printing. The prints of the files were made on polylactic acid filament on the Tevo Tarantula Pro printer. The bolus construction methodology using the software 3ds Max showed better results, as a greater contact area between the bolus and the phantom was observed when testing the fit of the printed bolus to the physical phantom. The 3D files of the virtual bolus will be available for future computer simulations. The printed bolus could be used in dosimetry with linear accelerators.

Key concepts: Bolus (digestion), Radiation therapy, Imaging phantom, Radiation treatment planning, Software, Nuclear medicine, Computer science, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
3D modeling of bolus for producing by prototyping and use in radiation therapy — Research Paper | ScholarLens