Photoacoustic spectroscopy-based ppb-level multi-gas sensor using symmetric multi-resonant cavity photoacoustic cell
Tailin Li, Chaotan Sima, Yan Ai, Tong Chen, Jinbiao Zhao, Zikai Zhao, Ping Lü
Abstract
Tailin Li, Chaotan Sima, Yan Ai, Tong Chen, Jinbiao Zhao, Zikai Zhao, Ping Lü
Abstract
In this paper, we propose and experimentally demonstrate a symmetric multi-resonant cavity photoacoustic cell (MR-PAC) with dual microphones detection, based on multi-resonator photoacoustic spectroscopy (MR-PAS). The designed photoacoustic cell contains three interconnected acoustic resonators to facilitate simultaneous control of three lasers for multi-gas sensing. Two microphones are symmetrically located at both sides of photoacoustic cell to implement two-point detection. The length of acoustic resonator is about 50 mm to minimize the photoacoustic cell, and the resonant frequency is around 3000 Hz. Feasibility and performance of the MR-PAC was demonstrated by simultaneous detection of C2H2, NO and CF4 using a near infrared diode laser and two mid infrared quantum cascade lasers. The minimum detection limits (MDLs) of C2H2, NO and CF4 are 480 ppb, 260 ppb and 0.57 ppb respectively with a 1 s integration time at normal atmospheric pressure. This minimized MR-PAS system is promising for the portable multi-gas sensing.
OpenAlex reports 69 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
In this paper, we propose and experimentally demonstrate a symmetric multi-resonant cavity photoacoustic cell (MR-PAC) with dual microphones detection, based on multi-resonator photoacoustic spectroscopy (MR-PAS). The designed photoacoustic cell contains three interconnected acoustic resonators to facilitate simultaneous control of three lasers for multi-gas sensing. Two microphones are symmetrically located at both sides of photoacoustic cell to implement two-point detection. The length of acoustic resonator is about 50 mm to minimize the photoacoustic cell, and the resonant frequency is around 3000 Hz. Feasibility and performance of the MR-PAC was demonstrated by simultaneous detection of C2H2, NO and CF4 using a near infrared diode laser and two mid infrared quantum cascade lasers. The minimum detection limits (MDLs) of C2H2, NO and CF4 are 480 ppb, 260 ppb and 0.57 ppb respectively with a 1 s integration time at normal atmospheric pressure. This minimized MR-PAS system is promising for the portable multi-gas sensing.
Key concepts: Photoacoustic spectroscopy, Quantum cascade laser, Photoacoustic imaging in biomedicine, Photoacoustic effect, Resonator, Materials science, Laser, Optoelectronics