A New Sensing Material for the Potentiometric Determination of Anionic Surfactants in Commercial Products
Olivera Galović, Mirela Samardžić, SanjaPetrusic, Milan Sak‐Bosnar
Abstract
Olivera Galović, Mirela Samardžić, SanjaPetrusic, Milan Sak‐Bosnar
Abstract
A new potentiometric sensor for the determination of anionic surfactants (ASs) was constructed based on the dimethyldioctadecylammonium-tetraphenylborate (DDA-TPB) ion pair as a sensing material. This sensitive, accurate, selective, rapid, simple and inexpensive sensor exhibited a Nernstian response for sodium dodecyl sulfate (NaDDS, 59.0 mV/decade) and sodium dodecylbenzene sulfonate (NaDBS, 59.1 mV/decade) over the range of 3∙10-7 to 8∙10-3 M for NaDDS and 4∙10-7 to 2∙10-3 M for NaDBS. The detection limits for both NaDDS and NaDBS were 2∙10-7 M. Different pH values, ionic strengths and commonly used nonionic surfactants, organic anions and inorganic anions did not have a significant influence on the sensor performances or the accuracy of ASs determination. The sensor was successfully applied to ASs determination in three commercial detergents with different percentages of ASs.
OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A new potentiometric sensor for the determination of anionic surfactants (ASs) was constructed based on the dimethyldioctadecylammonium-tetraphenylborate (DDA-TPB) ion pair as a sensing material. This sensitive, accurate, selective, rapid, simple and inexpensive sensor exhibited a Nernstian response for sodium dodecyl sulfate (NaDDS, 59.0 mV/decade) and sodium dodecylbenzene sulfonate (NaDBS, 59.1 mV/decade) over the range of 3∙10-7 to 8∙10-3 M for NaDDS and 4∙10-7 to 2∙10-3 M for NaDBS. The detection limits for both NaDDS and NaDBS were 2∙10-7 M. Different pH values, ionic strengths and commonly used nonionic surfactants, organic anions and inorganic anions did not have a significant influence on the sensor performances or the accuracy of ASs determination. The sensor was successfully applied to ASs determination in three commercial detergents with different percentages of ASs.
Key concepts: Dodecylbenzene, Potentiometric titration, Sodium tetraphenylborate, Tetraphenylborate, Potentiometric sensor, Chemistry, Sulfonate, Sodium