2023Research SquareOpen access

Evaluation of Submergence Limit and Head Loss in Flow Measuring Flumes Using Flow-3d Predictive Modeling

Saman Mostafazadeh Fard, Zohrab Samani

Open full text 0 citations

Abstract

Abstract Flow measurement is an important aspect of water management. Flumes are proven to be an effective method of measuring flow in channels. The accuracy of these flumes is dependent on the produced flume flow submergence ratio, limit, and head loss which are difficult to measure in the field. The aim of this manuscript was to evaluate the use of CFD platform FLOW-3D software for measuring these parameters in an experimental flume with flow rates of 0.112, 0.169, and 0.320 m^3/s named Flow 1, Flow 2, Flow 3 using CFD design of a flume with an elevated downstream bottom. FLOW-3D software was calibrated using published experimental (R^2 > 0.98 and RMSE < 1.5 cm). Submergence limit was measured at 0.21, 0.24, and 0.25, for Flow 1, Flow 2, and Flow 3, respectively. The maximum head loss when the submergence ratio exceeded its limit was measured at 32.5% for Flow 1.

Open-access reader

About this research paper

What this paper is about

Abstract Flow measurement is an important aspect of water management. Flumes are proven to be an effective method of measuring flow in channels. The accuracy of these flumes is dependent on the produced flume flow submergence ratio, limit, and head loss which are difficult to measure in the field. The aim of this manuscript was to evaluate the use of CFD platform FLOW-3D software for measuring these parameters in an experimental flume with flow rates of 0.112, 0.169, and 0.320 m^3/s named Flow 1, Flow 2, Flow 3 using CFD design of a flume with an elevated downstream bottom. FLOW-3D software was calibrated using published experimental (R^2 > 0.98 and RMSE < 1.5 cm). Submergence limit was measured at 0.21, 0.24, and 0.25, for Flow 1, Flow 2, and Flow 3, respectively. The maximum head loss when the submergence ratio exceeded its limit was measured at 32.5% for Flow 1.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Flow measurement is an important aspect of water management. Flumes are proven to be an effective method of measuring flow in channels. The accuracy of these flumes is dependent on the produced flume flow submergence ratio, limit, and head loss which are difficult to measure in the field. The aim of this manuscript was to evaluate the use of CFD platform FLOW-3D software for measuring these parameters in an experimental flume with flow rates of 0.112, 0.169, and 0.320 m^3/s named Flow 1, Flow 2, Flow 3 using CFD design of a flume with an elevated downstream bottom. FLOW-3D software was calibrated using published experimental (R^2 > 0.98 and RMSE < 1.5 cm). Submergence limit was measured at 0.21, 0.24, and 0.25, for Flow 1, Flow 2, and Flow 3, respectively. The maximum head loss when the submergence ratio exceeded its limit was measured at 32.5% for Flow 1.

Key concepts: Flume, Flow (mathematics), Flow measurement, Head (geology), Flow conditions, Mechanics, Limit (mathematics), Flow coefficient

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of Submergence Limit and Head Loss in Flow Measuring Flumes Using Flow-3d Predictive Modeling — Research Paper | ScholarLens