2023SustainabilityOpen access

Theoretical Study and Experimental Validation on the Applicable Refrigerant for Space Heating Air Source Heat Pump

Jinzhe Nie, Kaiqiao Wang, Xiangrui Kong, Han Zhang, Shuai Zhang

Open full text 9 citations

Abstract

The air source heat pump (ASHP) is developing rapidly and is widely used for space heating due to its potential for increasing energy efficiency and reducing greenhouse gas emissions. The choice of appropriate low global warming potential (GWP) alternative refrigerants is one of the challenges that ASHP systems face. Alternative refrigerants also affect the energy performance of these systems. Thus, it is essential to evaluate the performance of ASHP using environmentally friendly refrigerants to facilitate reasonable refrigerant selection. A theoretical model for simulating ASHP performance with different refrigerants is developed in this study. Experiments are conducted to validate the theoretical model. The simulation and the experimental results are found to be in good agreement. The ASHP performance indices, such as compression ratio (CR), discharging temperature (DT) and coefficients of performance (COP), are investigated using R22, R417A, R410A, R134a, R152a, R161 and R1234yf as working fluids. The results show that R152a has an average COP of 2.7% higher than R22, and R161 has an average COP of 1.4% higher than R22. R152a and R161 also have a higher CR but a lower DT than R22 under the same design conditions. In addition, R152a and R161 have ozone depletion potentials (ODP) of zero and extremely low GWPs; thus, they can be candidates to replace R22 in ASHP heating systems. This research provides a reference on refrigerant replacements for ASHP heating systems in North China.

Open-access reader

About this research paper

What this paper is about

The air source heat pump (ASHP) is developing rapidly and is widely used for space heating due to its potential for increasing energy efficiency and reducing greenhouse gas emissions. The choice of appropriate low global warming potential (GWP) alternative refrigerants is one of the challenges that ASHP systems face. Alternative refrigerants also affect the energy performance of these systems. Thus, it is essential to evaluate the performance of ASHP using environmentally friendly refrigerants to facilitate reasonable refrigerant selection. A theoretical model for simulating ASHP performance with different refrigerants is developed in this study. Experiments are conducted to validate the theoretical model. The simulation and the experimental results are found to be in good agreement. The ASHP performance indices, such as compression ratio (CR), discharging temperature (DT) and coefficients of performance (COP), are investigated using R22, R417A, R410A, R134a, R152a, R161 and R1234yf as working fluids. The results show that R152a has an average COP of 2.7% higher than R22, and R161 has an average COP of 1.4% higher than R22. R152a and R161 also have a higher CR but a lower DT than R22 under the same design conditions. In addition, R152a and R161 have ozone depletion potentials (ODP) of zero and extremely low GWPs; thus, they can be candidates to replace R22 in ASHP heating systems. This research provides a reference on refrigerant replacements for ASHP heating systems in North China.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The air source heat pump (ASHP) is developing rapidly and is widely used for space heating due to its potential for increasing energy efficiency and reducing greenhouse gas emissions. The choice of appropriate low global warming potential (GWP) alternative refrigerants is one of the challenges that ASHP systems face. Alternative refrigerants also affect the energy performance of these systems. Thus, it is essential to evaluate the performance of ASHP using environmentally friendly refrigerants to facilitate reasonable refrigerant selection. A theoretical model for simulating ASHP performance with different refrigerants is developed in this study. Experiments are conducted to validate the theoretical model. The simulation and the experimental results are found to be in good agreement. The ASHP performance indices, such as compression ratio (CR), discharging temperature (DT) and coefficients of performance (COP), are investigated using R22, R417A, R410A, R134a, R152a, R161 and R1234yf as working fluids. The results show that R152a has an average COP of 2.7% higher than R22, and R161 has an average COP of 1.4% higher than R22. R152a and R161 also have a higher CR but a lower DT than R22 under the same design conditions. In addition, R152a and R161 have ozone depletion potentials (ODP) of zero and extremely low GWPs; thus, they can be candidates to replace R22 in ASHP heating systems. This research provides a reference on refrigerant replacements for ASHP heating systems in North China.

Key concepts: Refrigerant, Air source heat pumps, Global-warming potential, Environmental science, Heat pump, Coefficient of performance, Process engineering, Greenhouse gas

Related papers

Back to paper searchBrowse research topicsOriginal source
Theoretical Study and Experimental Validation on the Applicable Refrigerant for Space Heating Air Source Heat Pump — Research Paper | ScholarLens