2023•CureusOpen access

The Glenoid Fossa’s Morphometric Investigation and Its Clinical Implications

Madhavi Tankala, Susmita Senapati, Shashi Shankar Behera, Satyanarayan Shamal

Open full text 7 citations

Abstract

Background The inconsistent morphology of the scapula is based on variable dimensions of its glenoid cavity, in addition to its broadened and truncated lateral angle. Its variable shapes are attributed to the spinoglenoid cavity (superior and posterior aspect of the scapula), which appears oval, inverted comma-shaped, and piriform (pear-shaped). Traumatic conditions often lead to glenoid dislocation/fracture. The precise administration of total shoulder arthroplasty with glenoid component adjustment warrants a comprehensive knowledge of scapular morphology. This study aims to assess the glenoid cavity/scapula shapes (anthropometric assessment) among individuals located in Odisha, India. Methods This cross-sectional analysis was undertaken on 74 left-sided and 70 right-sided, dry, and undeteriorated scapulae of human adult specimens obtained from the anatomy department irrespective of their gender and age. Results The glenoid cavity was most commonly inverted comma-shaped (34.02%) and pear-shaped (48.61%) while 17.36% of scapulae had oval-shaped glenoid cavities. The mean scapular breadth and length dimensions were 98.12±7.87mm and 135.76±12.85mm, respectively. Statistically insignificant bilateral variations were observed between the glenoid cavity index (mean value: 68.44±7.98%), glenoid diameter-2 (anteroposterior; mean value: 16.17±2.24mm), glenoid diameter-1 (anteroposterior; mean value: 22.67±1.53mm), and glenoid diameter (superoinferior; mean value: 36.03±2.15mm). Conclusion The size and shape of the glenoid cavity are directly associated with the dislocation of the shoulder joint and may disturb the results of total shoulder arthroplasty and rotator cuff surgeries. The current study analyzed the morphological types and diameters of the glenoid cavity in the scapulae to improve efficiency and lessen the failure proportions in shoulder arthroplasty. The study shows that morphological measurement of scapulae plays a vital role in the effective maintenance of posture and shoulder functions.

Open-access reader

About this research paper

What this paper is about

Background The inconsistent morphology of the scapula is based on variable dimensions of its glenoid cavity, in addition to its broadened and truncated lateral angle. Its variable shapes are attributed to the spinoglenoid cavity (superior and posterior aspect of the scapula), which appears oval, inverted comma-shaped, and piriform (pear-shaped). Traumatic conditions often lead to glenoid dislocation/fracture. The precise administration of total shoulder arthroplasty with glenoid component adjustment warrants a comprehensive knowledge of scapular morphology. This study aims to assess the glenoid cavity/scapula shapes (anthropometric assessment) among individuals located in Odisha, India. Methods This cross-sectional analysis was undertaken on 74 left-sided and 70 right-sided, dry, and undeteriorated scapulae of human adult specimens obtained from the anatomy department irrespective of their gender and age. Results The glenoid cavity was most commonly inverted comma-shaped (34.02%) and pear-shaped (48.61%) while 17.36% of scapulae had oval-shaped glenoid cavities. The mean scapular breadth and length dimensions were 98.12±7.87mm and 135.76±12.85mm, respectively. Statistically insignificant bilateral variations were observed between the glenoid cavity index (mean value: 68.44±7.98%), glenoid diameter-2 (anteroposterior; mean value: 16.17±2.24mm), glenoid diameter-1 (anteroposterior; mean value: 22.67±1.53mm), and glenoid diameter (superoinferior; mean value: 36.03±2.15mm). Conclusion The size and shape of the glenoid cavity are directly associated with the dislocation of the shoulder joint and may disturb the results of total shoulder arthroplasty and rotator cuff surgeries. The current study analyzed the morphological types and diameters of the glenoid cavity in the scapulae to improve efficiency and lessen the failure proportions in shoulder arthroplasty. The study shows that morphological measurement of scapulae plays a vital role in the effective maintenance of posture and shoulder functions.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background The inconsistent morphology of the scapula is based on variable dimensions of its glenoid cavity, in addition to its broadened and truncated lateral angle. Its variable shapes are attributed to the spinoglenoid cavity (superior and posterior aspect of the scapula), which appears oval, inverted comma-shaped, and piriform (pear-shaped). Traumatic conditions often lead to glenoid dislocation/fracture. The precise administration of total shoulder arthroplasty with glenoid component adjustment warrants a comprehensive knowledge of scapular morphology. This study aims to assess the glenoid cavity/scapula shapes (anthropometric assessment) among individuals located in Odisha, India. Methods This cross-sectional analysis was undertaken on 74 left-sided and 70 right-sided, dry, and undeteriorated scapulae of human adult specimens obtained from the anatomy department irrespective of their gender and age. Results The glenoid cavity was most commonly inverted comma-shaped (34.02%) and pear-shaped (48.61%) while 17.36% of scapulae had oval-shaped glenoid cavities. The mean scapular breadth and length dimensions were 98.12±7.87mm and 135.76±12.85mm, respectively. Statistically insignificant bilateral variations were observed between the glenoid cavity index (mean value: 68.44±7.98%), glenoid diameter-2 (anteroposterior; mean value: 16.17±2.24mm), glenoid diameter-1 (anteroposterior; mean value: 22.67±1.53mm), and glenoid diameter (superoinferior; mean value: 36.03±2.15mm). Conclusion The size and shape of the glenoid cavity are directly associated with the dislocation of the shoulder joint and may disturb the results of total shoulder arthroplasty and rotator cuff surgeries. The current study analyzed the morphological types and diameters of the glenoid cavity in the scapulae to improve efficiency and lessen the failure proportions in shoulder arthroplasty. The study shows that morphological measurement of scapulae plays a vital role in the effective maintenance of posture and shoulder functions.

Key concepts: Glenoid cavity, Scapula, Medicine, Fossa, Arthroplasty, Orthodontics, Anatomy, Shoulder joint

Related papers

Back to paper searchBrowse research topicsOriginal source
The Glenoid Fossa’s Morphometric Investigation and Its Clinical Implications — Research Paper | ScholarLens