2023International Journal of ThermofluidsOpen access

Flow distribution in microchannel devices with U-shaped manifolds

Fadi Alnaimat, Bobby Mathew

Open full text 13 citations

Abstract

This article investigates fluid distribution in multichannel microfluidic devices with U-shaped manifolds. The parameters investigated include Reynolds number, microchannel width, microchannel spacing width, and microchannel length. The study is carried out using a microfluidic device having 50 microchannels employing water as the working fluid. The flow distribution in the microfluidic device is investigated for microchannel widths between 100 µm to 500 µm and for Reynolds number ranging between 0.04 to 100. The effect of channel spacing width on flow distribution is investigated for microchannel spacing widths between 100 µm to 500 µm. The increase in Reynolds number affects the flow distribution by increasing the non-uniformity of the flow. It is found that increasing the microchannel width causes more non-uniformity in the flow. It is also found that increasing the microchannel spacing width decreased the non-uniformity of the flow distribution. It is found that increasing the channel width from 100 µm to 300 µm increased the flow maldistribution by 83%, and increasing the microchannel spacing width from 100 µm to 300 µm decreased the flow maldistribution by 42%. It is observed that the microchannel width has a stronger influence on the flow distribution compared with microchannel spacing width. The study is useful for examining the flow maldistribution in microfluidic devices as their performance is dependent on flow rate.

About this research paper

What this paper is about

This article investigates fluid distribution in multichannel microfluidic devices with U-shaped manifolds. The parameters investigated include Reynolds number, microchannel width, microchannel spacing width, and microchannel length. The study is carried out using a microfluidic device having 50 microchannels employing water as the working fluid. The flow distribution in the microfluidic device is investigated for microchannel widths between 100 µm to 500 µm and for Reynolds number ranging between 0.04 to 100. The effect of channel spacing width on flow distribution is investigated for microchannel spacing widths between 100 µm to 500 µm. The increase in Reynolds number affects the flow distribution by increasing the non-uniformity of the flow. It is found that increasing the microchannel width causes more non-uniformity in the flow. It is also found that increasing the microchannel spacing width decreased the non-uniformity of the flow distribution. It is found that increasing the channel width from 100 µm to 300 µm increased the flow maldistribution by 83%, and increasing the microchannel spacing width from 100 µm to 300 µm decreased the flow maldistribution by 42%. It is observed that the microchannel width has a stronger influence on the flow distribution compared with microchannel spacing width. The study is useful for examining the flow maldistribution in microfluidic devices as their performance is dependent on flow rate.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This article investigates fluid distribution in multichannel microfluidic devices with U-shaped manifolds. The parameters investigated include Reynolds number, microchannel width, microchannel spacing width, and microchannel length. The study is carried out using a microfluidic device having 50 microchannels employing water as the working fluid. The flow distribution in the microfluidic device is investigated for microchannel widths between 100 µm to 500 µm and for Reynolds number ranging between 0.04 to 100. The effect of channel spacing width on flow distribution is investigated for microchannel spacing widths between 100 µm to 500 µm. The increase in Reynolds number affects the flow distribution by increasing the non-uniformity of the flow. It is found that increasing the microchannel width causes more non-uniformity in the flow. It is also found that increasing the microchannel spacing width decreased the non-uniformity of the flow distribution. It is found that increasing the channel width from 100 µm to 300 µm increased the flow maldistribution by 83%, and increasing the microchannel spacing width from 100 µm to 300 µm decreased the flow maldistribution by 42%. It is observed that the microchannel width has a stronger influence on the flow distribution compared with microchannel spacing width. The study is useful for examining the flow maldistribution in microfluidic devices as their performance is dependent on flow rate.

Key concepts: Microchannel, Reynolds number, Flow (mathematics), Microfluidics, Materials science, Mechanics, Volumetric flow rate, Hydraulic diameter

Related papers

Back to paper searchBrowse research topicsOriginal source
Flow distribution in microchannel devices with U-shaped manifolds — Research Paper | ScholarLens