2023•NEJM EvidenceOpen access

Apixaban or Warfarin in Patients with an On-X Mechanical Aortic Valve

Tracy Y. Wang, Lars Georg Svensson, Jun Wen, Andrew M. Vekstein, Marc Gerdisch, Vijay U. Rao, Michael G. Moront, Doug Johnston, Renato D. Lópes, Alma Chavez, Marc Ruel, Eugene H. Blackstone, Richard C. Becker, Vinod H. Thourani, John D. Puskas, Hussein R. Al‐Khalidi, David G. Cable, John Alex Elefteriades, Alberto A. Pochettino, J. Alan Wolfe, Allen H. Graeve, Ibrahim S. Sultan, Ashraf A. Sabe, Héctor I. Michelena, John Hunter Alexander

Open full text 124 citations

Abstract

BACKGROUND: Vitamin K antagonists are the only oral anticoagulants approved to prevent valve thrombosis and valve-related thromboembolism in patients with mechanical heart valves. Whether patients with an On-X mechanical aortic valve can be safely anticoagulated with apixaban is unknown. METHODS: Patients with an On-X aortic valve implanted at least 3 months before enrollment were randomly assigned to receive apixaban 5 mg twice daily or warfarin (target international normalized ratio 2.0 to 3.0). The primary efficacy end point was the composite of valve thrombosis or valve-related thromboembolism with coprimary analyses comparing apixaban with warfarin for noninferiority and comparing the apixaban event rate with an objective performance criterion (OPC). RESULTS: The trial was stopped after 863 participants were enrolled owing to an excess of thromboembolic events in the apixaban group. Most (94%) participants took aspirin. A total of 26 primary end-point events occurred, 20 (in 16 participants) in the apixaban group (4.2%/patient-year; 95% confidence interval [CI], 2.3 to 6.0) and 6 (in 6 participants) in the warfarin group (1.3%/patient-year; 95% CI, 0.3 to 2.3). The difference in primary end-point rates between the apixaban and warfarin groups was 2.9 (95% CI, 0.8 to 5.0); noninferiority and OPC success criteria were not met. Major bleeding rates were 3.6%/patient-year with apixaban and 4.5%/patient-year with warfarin. CONCLUSIONS: Apixaban did not demonstrate noninferiority to warfarin and is less effective than warfarin for the prevention of valve thrombosis or thromboembolism in patients with an On-X mechanical aortic valve. (Funded by Artivion; ClinicalTrials.gov number, NCT04142658.)

Open-access reader

About this research paper

What this paper is about

BACKGROUND: Vitamin K antagonists are the only oral anticoagulants approved to prevent valve thrombosis and valve-related thromboembolism in patients with mechanical heart valves. Whether patients with an On-X mechanical aortic valve can be safely anticoagulated with apixaban is unknown. METHODS: Patients with an On-X aortic valve implanted at least 3 months before enrollment were randomly assigned to receive apixaban 5 mg twice daily or warfarin (target international normalized ratio 2.0 to 3.0). The primary efficacy end point was the composite of valve thrombosis or valve-related thromboembolism with coprimary analyses comparing apixaban with warfarin for noninferiority and comparing the apixaban event rate with an objective performance criterion (OPC). RESULTS: The trial was stopped after 863 participants were enrolled owing to an excess of thromboembolic events in the apixaban group. Most (94%) participants took aspirin. A total of 26 primary end-point events occurred, 20 (in 16 participants) in the apixaban group (4.2%/patient-year; 95% confidence interval [CI], 2.3 to 6.0) and 6 (in 6 participants) in the warfarin group (1.3%/patient-year; 95% CI, 0.3 to 2.3). The difference in primary end-point rates between the apixaban and warfarin groups was 2.9 (95% CI, 0.8 to 5.0); noninferiority and OPC success criteria were not met. Major bleeding rates were 3.6%/patient-year with apixaban and 4.5%/patient-year with warfarin. CONCLUSIONS: Apixaban did not demonstrate noninferiority to warfarin and is less effective than warfarin for the prevention of valve thrombosis or thromboembolism in patients with an On-X mechanical aortic valve. (Funded by Artivion; ClinicalTrials.gov number, NCT04142658.)

Why it matters

OpenAlex reports 124 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Vitamin K antagonists are the only oral anticoagulants approved to prevent valve thrombosis and valve-related thromboembolism in patients with mechanical heart valves. Whether patients with an On-X mechanical aortic valve can be safely anticoagulated with apixaban is unknown. METHODS: Patients with an On-X aortic valve implanted at least 3 months before enrollment were randomly assigned to receive apixaban 5 mg twice daily or warfarin (target international normalized ratio 2.0 to 3.0). The primary efficacy end point was the composite of valve thrombosis or valve-related thromboembolism with coprimary analyses comparing apixaban with warfarin for noninferiority and comparing the apixaban event rate with an objective performance criterion (OPC). RESULTS: The trial was stopped after 863 participants were enrolled owing to an excess of thromboembolic events in the apixaban group. Most (94%) participants took aspirin. A total of 26 primary end-point events occurred, 20 (in 16 participants) in the apixaban group (4.2%/patient-year; 95% confidence interval [CI], 2.3 to 6.0) and 6 (in 6 participants) in the warfarin group (1.3%/patient-year; 95% CI, 0.3 to 2.3). The difference in primary end-point rates between the apixaban and warfarin groups was 2.9 (95% CI, 0.8 to 5.0); noninferiority and OPC success criteria were not met. Major bleeding rates were 3.6%/patient-year with apixaban and 4.5%/patient-year with warfarin. CONCLUSIONS: Apixaban did not demonstrate noninferiority to warfarin and is less effective than warfarin for the prevention of valve thrombosis or thromboembolism in patients with an On-X mechanical aortic valve. (Funded by Artivion; ClinicalTrials.gov number, NCT04142658.)

Key concepts: Apixaban, Warfarin, Medicine, Mechanical heart-valve, PIEZO1, Internal medicine, Cardiology, Mechanical heart

Related papers

Back to paper searchBrowse research topicsOriginal source
Apixaban or Warfarin in Patients with an On-X Mechanical Aortic Valve — Research Paper | ScholarLens