2023Preprints.orgOpen access

Performance of Non-compliant Reinforced Concrete Frame Structures Under Seismic Loading

Edy Purwanto, Stefanus Adi Kristiawan, Senot Sangadji, Halwan Alfisa Saifullah

Open full text 1 citations

Abstract

Non-compliant (NC) structures are often encountered in building construction in developing countries. This is a condition whereby erected buildings do not follow regulatory standards, especially in the provision of reinforcements. Therefore, under an earthquake load, the structures do not have sufficient resistance against such load. The structural elements of the building, which often have NC conditions, are the beam-column joints because they do not contain adequate shear reinforcements due to installation difficulty. This study aims to determine the structural performance of the reinforced concrete (RC) frame, which has a reinforcement deficiency in the beam-column joints. Numerical simulation was conducted on the Kakaletsis structure model by modifying the reinforcement details at the joints to represent the NC conditions. The non-linear modeling and analysis of the structural model were carried out using ATENA software. The analysis showed that the reduction in shear reinforcements in the NC model joint caused a decrease in load-carrying capacity by about 26.04%. A shift was also observed in the collapse pattern, i.e., from the beam to the end of the column, causing global failure and reducing the undamaged but increasing more severely damaged condition. This showed that the NC structure, due to the non-conformance of reinforcement, significantly reduced the structure's performance.

Open-access reader

About this research paper

What this paper is about

Non-compliant (NC) structures are often encountered in building construction in developing countries. This is a condition whereby erected buildings do not follow regulatory standards, especially in the provision of reinforcements. Therefore, under an earthquake load, the structures do not have sufficient resistance against such load. The structural elements of the building, which often have NC conditions, are the beam-column joints because they do not contain adequate shear reinforcements due to installation difficulty. This study aims to determine the structural performance of the reinforced concrete (RC) frame, which has a reinforcement deficiency in the beam-column joints. Numerical simulation was conducted on the Kakaletsis structure model by modifying the reinforcement details at the joints to represent the NC conditions. The non-linear modeling and analysis of the structural model were carried out using ATENA software. The analysis showed that the reduction in shear reinforcements in the NC model joint caused a decrease in load-carrying capacity by about 26.04%. A shift was also observed in the collapse pattern, i.e., from the beam to the end of the column, causing global failure and reducing the undamaged but increasing more severely damaged condition. This showed that the NC structure, due to the non-conformance of reinforcement, significantly reduced the structure's performance.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Non-compliant (NC) structures are often encountered in building construction in developing countries. This is a condition whereby erected buildings do not follow regulatory standards, especially in the provision of reinforcements. Therefore, under an earthquake load, the structures do not have sufficient resistance against such load. The structural elements of the building, which often have NC conditions, are the beam-column joints because they do not contain adequate shear reinforcements due to installation difficulty. This study aims to determine the structural performance of the reinforced concrete (RC) frame, which has a reinforcement deficiency in the beam-column joints. Numerical simulation was conducted on the Kakaletsis structure model by modifying the reinforcement details at the joints to represent the NC conditions. The non-linear modeling and analysis of the structural model were carried out using ATENA software. The analysis showed that the reduction in shear reinforcements in the NC model joint caused a decrease in load-carrying capacity by about 26.04%. A shift was also observed in the collapse pattern, i.e., from the beam to the end of the column, causing global failure and reducing the undamaged but increasing more severely damaged condition. This showed that the NC structure, due to the non-conformance of reinforcement, significantly reduced the structure's performance.

Key concepts: Structural engineering, Reinforcement, Reinforced concrete, Frame (networking), Joint (building), Beam (structure), Seismic loading, Column (typography)

Related papers

Back to paper searchBrowse research topicsOriginal source
Performance of Non-compliant Reinforced Concrete Frame Structures Under Seismic Loading — Research Paper | ScholarLens