2023Arthroplasty TodayOpen access

Primary Stability of Collared and Collarless Cementless Femoral Stems – A Finite Element Analysis Study

Ryunosuke Watanabe, Hajime Mishima, Sho Totsuka, Tomofumi Nishino, Masashi Yamazaki

Open full text 31 citations

Abstract

Background: Primary stability of the femoral stem is important for the long-term results of cementless total hip arthroplasty. Cementless collared stems have been known to have higher stability than collarless stems when there is a contact between the collar and the calcar. The purpose of this study was to compare the stabilities of collared stem and collarless stem in 2 loading conditions: 1) flat walking and 2) stair climbing. Methods: We constructed 3 finite element models. In the first model, the collar had contact with the calcar. The second model had a 1 mm gap between the calcar and the collar. The third model was constructed with a collarless stem. The proximal femur around the stem was divided into 3 zones: the upper zone (Gruen zones 1 and 7), the middle zone (Gruen zones 2 and 6), and the lower zone (Gruen zones 3 and 5). The micromotion at the stem/bone interface was measured at each zone of the 3 models under the 2 loading conditions. Results: The results showed that collared stems were more stable when the collar was in contact with the calcar than when a gap was left between the collar and the calcar. In particular, collar contact was highly effective in suppressing the micromotion proximal to the stem. Conclusions: Compared to the collarless stem, the collared stem had comparable stability when there was a gap at the collar and calcar interface and higher stability when there was contact between the collar and the calcar.

Open-access reader

About this research paper

What this paper is about

Background: Primary stability of the femoral stem is important for the long-term results of cementless total hip arthroplasty. Cementless collared stems have been known to have higher stability than collarless stems when there is a contact between the collar and the calcar. The purpose of this study was to compare the stabilities of collared stem and collarless stem in 2 loading conditions: 1) flat walking and 2) stair climbing. Methods: We constructed 3 finite element models. In the first model, the collar had contact with the calcar. The second model had a 1 mm gap between the calcar and the collar. The third model was constructed with a collarless stem. The proximal femur around the stem was divided into 3 zones: the upper zone (Gruen zones 1 and 7), the middle zone (Gruen zones 2 and 6), and the lower zone (Gruen zones 3 and 5). The micromotion at the stem/bone interface was measured at each zone of the 3 models under the 2 loading conditions. Results: The results showed that collared stems were more stable when the collar was in contact with the calcar than when a gap was left between the collar and the calcar. In particular, collar contact was highly effective in suppressing the micromotion proximal to the stem. Conclusions: Compared to the collarless stem, the collared stem had comparable stability when there was a gap at the collar and calcar interface and higher stability when there was contact between the collar and the calcar.

Why it matters

OpenAlex reports 31 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background: Primary stability of the femoral stem is important for the long-term results of cementless total hip arthroplasty. Cementless collared stems have been known to have higher stability than collarless stems when there is a contact between the collar and the calcar. The purpose of this study was to compare the stabilities of collared stem and collarless stem in 2 loading conditions: 1) flat walking and 2) stair climbing. Methods: We constructed 3 finite element models. In the first model, the collar had contact with the calcar. The second model had a 1 mm gap between the calcar and the collar. The third model was constructed with a collarless stem. The proximal femur around the stem was divided into 3 zones: the upper zone (Gruen zones 1 and 7), the middle zone (Gruen zones 2 and 6), and the lower zone (Gruen zones 3 and 5). The micromotion at the stem/bone interface was measured at each zone of the 3 models under the 2 loading conditions. Results: The results showed that collared stems were more stable when the collar was in contact with the calcar than when a gap was left between the collar and the calcar. In particular, collar contact was highly effective in suppressing the micromotion proximal to the stem. Conclusions: Compared to the collarless stem, the collared stem had comparable stability when there was a gap at the collar and calcar interface and higher stability when there was contact between the collar and the calcar.

Key concepts: Calcar, Collar, Femur, Medicine, Orthodontics, Materials science, Dentistry, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Primary Stability of Collared and Collarless Cementless Femoral Stems – A Finite Element Analysis Study — Research Paper | ScholarLens