2023Unpublished venueOpen access

Investigation on Sampling Flow Rate Calibration Method of Air Sampler

Song Jin, Chao Chen, Yiping Liu, Haiyang Li

Open full text 0 citations

Abstract

In order to obtain the most accurate and effective sampling flow rate calibration method of air sampler, several different equipments were used under two different installation conditions in this paper.According to the experimental results, the calibration results of ultrasonic flowmeter and special orifice flowmeter will be affected by the installation conditions.Consequently, while ultrasonic flowmeter and special orifice flowmeter are used to sampling flow rate calibration, it is necessary to first calibrate the two flowmeters with filter paper, and then use the corrected results to calibrate the sampling flow rate.Based on the results of further experiments, calibration datas of gas roots flowmeter and special orifice flowmeter are consistent with the results obtained from gas flow standard facilities by negative pressure method, at the same time, there is still an error of 3%~5% when corrected ultrasonic flowmeter is used.Therefore, gas flow standard facilities by negative pressure method and gas roots flowmeter can be directly used for sampling flow rate calibration of air sampler, if it is not convenient , special orifice flowmeter which calibrated with filter paper is also a good choice, ultrasonic flowmeter is not recommended.

Open-access reader

About this research paper

What this paper is about

In order to obtain the most accurate and effective sampling flow rate calibration method of air sampler, several different equipments were used under two different installation conditions in this paper.According to the experimental results, the calibration results of ultrasonic flowmeter and special orifice flowmeter will be affected by the installation conditions.Consequently, while ultrasonic flowmeter and special orifice flowmeter are used to sampling flow rate calibration, it is necessary to first calibrate the two flowmeters with filter paper, and then use the corrected results to calibrate the sampling flow rate.Based on the results of further experiments, calibration datas of gas roots flowmeter and special orifice flowmeter are consistent with the results obtained from gas flow standard facilities by negative pressure method, at the same time, there is still an error of 3%~5% when corrected ultrasonic flowmeter is used.Therefore, gas flow standard facilities by negative pressure method and gas roots flowmeter can be directly used for sampling flow rate calibration of air sampler, if it is not convenient , special orifice flowmeter which calibrated with filter paper is also a good choice, ultrasonic flowmeter is not recommended.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In order to obtain the most accurate and effective sampling flow rate calibration method of air sampler, several different equipments were used under two different installation conditions in this paper.According to the experimental results, the calibration results of ultrasonic flowmeter and special orifice flowmeter will be affected by the installation conditions.Consequently, while ultrasonic flowmeter and special orifice flowmeter are used to sampling flow rate calibration, it is necessary to first calibrate the two flowmeters with filter paper, and then use the corrected results to calibrate the sampling flow rate.Based on the results of further experiments, calibration datas of gas roots flowmeter and special orifice flowmeter are consistent with the results obtained from gas flow standard facilities by negative pressure method, at the same time, there is still an error of 3%~5% when corrected ultrasonic flowmeter is used.Therefore, gas flow standard facilities by negative pressure method and gas roots flowmeter can be directly used for sampling flow rate calibration of air sampler, if it is not convenient , special orifice flowmeter which calibrated with filter paper is also a good choice, ultrasonic flowmeter is not recommended.

Key concepts: Flow measurement, Ultrasonic flow meter, Calibration, Body orifice, Volumetric flow rate, Orifice plate, Ultrasonic sensor, Sampling (signal processing)

Related papers

Back to paper searchBrowse research topicsOriginal source