Research on emissivity of surface blackbody with microarray structure based on Monte-Carlo method

GANG WANG, CAIJUAN XIA, XIAOPENG HAO, Jian Song, JINGJING ZHOU, Ruiheng Sima, ZHIYI LIU

Open publisher page 1 citations

Abstract

The surface-source blackbody is widely used in infrared remote sensing and other fields as a calibration source to calibrate infrared loads by providing accurate infrared radiation, and the effective emissivity of the surface-source blackbody is one of the important parameters for the calibration of infrared devices, which directly determines the accuracy of calibration. In this paper, two microarray structure models, ideal and non-ideal cases, are established around the effective emissivity of the surface-source blackbody radiating surface, and simulation experiments based on Monte-Carlo method (MCM)are carried out. The effective emissivity of the blackbody radiation source is analyzed to be influenced by the geometrical parameters of the microcavity structure, the emissivity of the surface coating and different angles. The effective emissivity increases with the decrease of the base height ratio of the pyramidal microcavity structure, and the emissivity of the surface coating material is linearly increasing, and the linearity of the two models is better than 0.9997. The effective emissivity of the ideal and non-ideal models has a small trend in the vertical direction and horizon direction angle 0-±10°, and the standard deviation is less than 0.15%, which has high stability. The results of the study can provide theoretical guidance for the enhancement of the effective emissivity of the surface-source blackbody.

About this research paper

What this paper is about

The surface-source blackbody is widely used in infrared remote sensing and other fields as a calibration source to calibrate infrared loads by providing accurate infrared radiation, and the effective emissivity of the surface-source blackbody is one of the important parameters for the calibration of infrared devices, which directly determines the accuracy of calibration. In this paper, two microarray structure models, ideal and non-ideal cases, are established around the effective emissivity of the surface-source blackbody radiating surface, and simulation experiments based on Monte-Carlo method (MCM)are carried out. The effective emissivity of the blackbody radiation source is analyzed to be influenced by the geometrical parameters of the microcavity structure, the emissivity of the surface coating and different angles. The effective emissivity increases with the decrease of the base height ratio of the pyramidal microcavity structure, and the emissivity of the surface coating material is linearly increasing, and the linearity of the two models is better than 0.9997. The effective emissivity of the ideal and non-ideal models has a small trend in the vertical direction and horizon direction angle 0-±10°, and the standard deviation is less than 0.15%, which has high stability. The results of the study can provide theoretical guidance for the enhancement of the effective emissivity of the surface-source blackbody.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The surface-source blackbody is widely used in infrared remote sensing and other fields as a calibration source to calibrate infrared loads by providing accurate infrared radiation, and the effective emissivity of the surface-source blackbody is one of the important parameters for the calibration of infrared devices, which directly determines the accuracy of calibration. In this paper, two microarray structure models, ideal and non-ideal cases, are established around the effective emissivity of the surface-source blackbody radiating surface, and simulation experiments based on Monte-Carlo method (MCM)are carried out. The effective emissivity of the blackbody radiation source is analyzed to be influenced by the geometrical parameters of the microcavity structure, the emissivity of the surface coating and different angles. The effective emissivity increases with the decrease of the base height ratio of the pyramidal microcavity structure, and the emissivity of the surface coating material is linearly increasing, and the linearity of the two models is better than 0.9997. The effective emissivity of the ideal and non-ideal models has a small trend in the vertical direction and horizon direction angle 0-±10°, and the standard deviation is less than 0.15%, which has high stability. The results of the study can provide theoretical guidance for the enhancement of the effective emissivity of the surface-source blackbody.

Key concepts: Emissivity, Black-body radiation, Infrared, Optics, Monte Carlo method, Calibration, Radiation, Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Research on emissivity of surface blackbody with microarray structure based on Monte-Carlo method — Research Paper | ScholarLens