2023The Journal of AdhesionRequires access

Capillary forces and capillary bridges between a three-finger microgripper and a plate

Zenghua Fan, Zixiao Liu, Congcong Huang, Han Wang, Ming Fan, Lefeng Wang

Open publisher page 4 citations

Abstract

The presence of surface tension in liquids, which induces a strong capillary force between wetting particles in micro/nano scale, has aroused extensive attention. In present study, a fundamental investigation on capillary forces and rupture behaviors of capillary bridges between a three-finger microgripper and a plate is conducted in quasi-static state. Theoretical analysis is performed for solutions of the capillary force. The capillary bridges between a three-finger microgripper and a plate are established based on the principle of energy minimization. An analytical approach for computing the capillary force for the three-finger/plate geometry is proposed by means of variables obtained from the simulation models. The comparison of the single-finger capillary bridge and three-finger capillary bridge is investigated based on the developed models. The effects of separation distance, capillary bridge volume, radial distance and contact angle on the capillary force of three-finger capillary bridges are analyzed in detail. The results demonstrate that the variation of capillary force with separation distance and volume changing is not monotonic, which is caused by the edge effect of the three-finger microgripper. Capillary force measurements were experimentally characterized to demonstrate the reliability of the simulation models and the capillary force solution method based on an established experimental platform.

About this research paper

What this paper is about

The presence of surface tension in liquids, which induces a strong capillary force between wetting particles in micro/nano scale, has aroused extensive attention. In present study, a fundamental investigation on capillary forces and rupture behaviors of capillary bridges between a three-finger microgripper and a plate is conducted in quasi-static state. Theoretical analysis is performed for solutions of the capillary force. The capillary bridges between a three-finger microgripper and a plate are established based on the principle of energy minimization. An analytical approach for computing the capillary force for the three-finger/plate geometry is proposed by means of variables obtained from the simulation models. The comparison of the single-finger capillary bridge and three-finger capillary bridge is investigated based on the developed models. The effects of separation distance, capillary bridge volume, radial distance and contact angle on the capillary force of three-finger capillary bridges are analyzed in detail. The results demonstrate that the variation of capillary force with separation distance and volume changing is not monotonic, which is caused by the edge effect of the three-finger microgripper. Capillary force measurements were experimentally characterized to demonstrate the reliability of the simulation models and the capillary force solution method based on an established experimental platform.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The presence of surface tension in liquids, which induces a strong capillary force between wetting particles in micro/nano scale, has aroused extensive attention. In present study, a fundamental investigation on capillary forces and rupture behaviors of capillary bridges between a three-finger microgripper and a plate is conducted in quasi-static state. Theoretical analysis is performed for solutions of the capillary force. The capillary bridges between a three-finger microgripper and a plate are established based on the principle of energy minimization. An analytical approach for computing the capillary force for the three-finger/plate geometry is proposed by means of variables obtained from the simulation models. The comparison of the single-finger capillary bridge and three-finger capillary bridge is investigated based on the developed models. The effects of separation distance, capillary bridge volume, radial distance and contact angle on the capillary force of three-finger capillary bridges are analyzed in detail. The results demonstrate that the variation of capillary force with separation distance and volume changing is not monotonic, which is caused by the edge effect of the three-finger microgripper. Capillary force measurements were experimentally characterized to demonstrate the reliability of the simulation models and the capillary force solution method based on an established experimental platform.

Key concepts: Capillary action, Materials science, Mechanics, Capillary surface, Wetting, Capillary number, Surface tension, Capillary length

Related papers

Back to paper searchBrowse research topicsOriginal source
Capillary forces and capillary bridges between a three-finger microgripper and a plate — Research Paper | ScholarLens