Transformer Differential Protection System Testing for Scholarly Benefits Using RTDS Hardware-in-the-Loop Technique

Sinawo Nomandela, Mkhululi Elvis Siyanda Mnguni, Mukovhe Ratshitanga, Sikho Ntshiba

Open publisher page 5 citations

Abstract

The hardware-in-the-loop (HIL) test for a transformer differential protection system is presented in this paper, to prove the validity of the settings configuration of the relay. A step-by-step configuration is done up to the testing part, which proves and validates the concept of differential calculations. The steps and configuration procedures presented in this paper will help other scholars understand the configuration and the operating principle of the transformer differential protection system and its elements. The focus of this study is not limited to the protected transformer, it also considers the system in which the transformer is employed. The obtained simulation results demonstrate that the configuration of the protection system is successful. This was observed through the human-machine interface (HMI) of the relay.

About this research paper

What this paper is about

The hardware-in-the-loop (HIL) test for a transformer differential protection system is presented in this paper, to prove the validity of the settings configuration of the relay. A step-by-step configuration is done up to the testing part, which proves and validates the concept of differential calculations. The steps and configuration procedures presented in this paper will help other scholars understand the configuration and the operating principle of the transformer differential protection system and its elements. The focus of this study is not limited to the protected transformer, it also considers the system in which the transformer is employed. The obtained simulation results demonstrate that the configuration of the protection system is successful. This was observed through the human-machine interface (HMI) of the relay.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The hardware-in-the-loop (HIL) test for a transformer differential protection system is presented in this paper, to prove the validity of the settings configuration of the relay. A step-by-step configuration is done up to the testing part, which proves and validates the concept of differential calculations. The steps and configuration procedures presented in this paper will help other scholars understand the configuration and the operating principle of the transformer differential protection system and its elements. The focus of this study is not limited to the protected transformer, it also considers the system in which the transformer is employed. The obtained simulation results demonstrate that the configuration of the protection system is successful. This was observed through the human-machine interface (HMI) of the relay.

Key concepts: Differential protection, Transformer, Relay, Protective relay, Computer science, Current transformer, Linear variable differential transformer, Electronic engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Transformer Differential Protection System Testing for Scholarly Benefits Using RTDS Hardware-in-the-Loop Technique — Research Paper | ScholarLens