2023Digital HealthOpen access

The utility of phonocardiograms in real-time remote cardiac auscultation using an internet-connected electronic stethoscope: Open-label randomized controlled pilot trial

Takanobu Hirosawa, Takahiro Ito, Yukinori Harada, Kohei Ikenoya, Masashi Yokose, Taro Shimizu

Open full text 4 citations

Abstract

Background: We have shown classical cardiac auscultation was superior to remote auscultation. We developed a phonocardiogram system to visualize sounds in remote auscultation. Objective: This study aimed to evaluate the effect of phonocardiograms on the diagnostic accuracy in remote auscultation using a cardiology patient simulator. Methods: In this open-label randomized controlled pilot trial, we randomly assigned physicians to the real-time remote auscultation group (control group) or the real-time remote auscultation with the phonocardiogram group (intervention group). Participants attended a training session in which they auscultated 15 sounds with the correct classification. After that, participants attended a test session where they had to classify 10 sounds. The control group auscultated the sounds remotely using an electronic stethoscope, an online medical program and a 4-K TV speaker without watching the TV screen. The intervention group performed auscultation like the control group but watched the phonocardiogram on the TV screen. The primary and secondary outcomes were the total test scores and each sound score, respectively. Results: = .06). The correct answer rates of each sound were not different. Valvular/irregular rhythm sounds were not misclassified as normal sounds in the intervention group. Conclusions: Using a phonocardiogram improved the total correct answer rate by more than 10% in remote auscultation, although statistically insignificant. The phonocardiogram could help physicians screen valvular/irregular rhythm sounds from normal sounds. Trial registration: UMIN-CTR UMIN000045271; https://upload.umin.ac.jp/cgi-open-bin/ctr/ctr_view.cgi?recptno=R000051710.

About this research paper

What this paper is about

Background: We have shown classical cardiac auscultation was superior to remote auscultation. We developed a phonocardiogram system to visualize sounds in remote auscultation. Objective: This study aimed to evaluate the effect of phonocardiograms on the diagnostic accuracy in remote auscultation using a cardiology patient simulator. Methods: In this open-label randomized controlled pilot trial, we randomly assigned physicians to the real-time remote auscultation group (control group) or the real-time remote auscultation with the phonocardiogram group (intervention group). Participants attended a training session in which they auscultated 15 sounds with the correct classification. After that, participants attended a test session where they had to classify 10 sounds. The control group auscultated the sounds remotely using an electronic stethoscope, an online medical program and a 4-K TV speaker without watching the TV screen. The intervention group performed auscultation like the control group but watched the phonocardiogram on the TV screen. The primary and secondary outcomes were the total test scores and each sound score, respectively. Results: = .06). The correct answer rates of each sound were not different. Valvular/irregular rhythm sounds were not misclassified as normal sounds in the intervention group. Conclusions: Using a phonocardiogram improved the total correct answer rate by more than 10% in remote auscultation, although statistically insignificant. The phonocardiogram could help physicians screen valvular/irregular rhythm sounds from normal sounds. Trial registration: UMIN-CTR UMIN000045271; https://upload.umin.ac.jp/cgi-open-bin/ctr/ctr_view.cgi?recptno=R000051710.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background: We have shown classical cardiac auscultation was superior to remote auscultation. We developed a phonocardiogram system to visualize sounds in remote auscultation. Objective: This study aimed to evaluate the effect of phonocardiograms on the diagnostic accuracy in remote auscultation using a cardiology patient simulator. Methods: In this open-label randomized controlled pilot trial, we randomly assigned physicians to the real-time remote auscultation group (control group) or the real-time remote auscultation with the phonocardiogram group (intervention group). Participants attended a training session in which they auscultated 15 sounds with the correct classification. After that, participants attended a test session where they had to classify 10 sounds. The control group auscultated the sounds remotely using an electronic stethoscope, an online medical program and a 4-K TV speaker without watching the TV screen. The intervention group performed auscultation like the control group but watched the phonocardiogram on the TV screen. The primary and secondary outcomes were the total test scores and each sound score, respectively. Results: = .06). The correct answer rates of each sound were not different. Valvular/irregular rhythm sounds were not misclassified as normal sounds in the intervention group. Conclusions: Using a phonocardiogram improved the total correct answer rate by more than 10% in remote auscultation, although statistically insignificant. The phonocardiogram could help physicians screen valvular/irregular rhythm sounds from normal sounds. Trial registration: UMIN-CTR UMIN000045271; https://upload.umin.ac.jp/cgi-open-bin/ctr/ctr_view.cgi?recptno=R000051710.

Key concepts: Phonocardiogram, Auscultation, Stethoscope, Medicine, Heart sounds, Heart Auscultation, Sound (geography), Randomized controlled trial

Related papers

Back to paper searchBrowse research topicsOriginal source
The utility of phonocardiograms in real-time remote cardiac auscultation using an internet-connected electronic stethoscope: Open-label randomized controlled pilot trial — Research Paper | ScholarLens