Abstract

Inverse dynamics analysis of prosthetic legs with polycentric knees is complex due to increased number of links. The present work proposes a simple and general method called equivalent system (ES) analysis. The ES analysis provides forces and moment at hip joint as well as at the functional knee centre (FKC), the instant centre of the polycentric knee. The input to the ES analysis is the motion data. For validation of the proposed method, synthetic motion data for the swing phase of walking with prosthetic legs having different knees are generated by simulations using ADAMS. The hip kinetics evaluated by the proposed method is compared with that from ADAMS. The root mean square errors of the ES analysis are lower than 17 (10 −6 ) N for hip reaction forces and 2.6 (10 −6 ) Nm for the hip moments, thereby validating the proposed method. In order to demonstrate the application of the proposed methodology, the motion data of two transfemoral amputees using single-axis and four-bar knee prostheses are obtained during gait trials. The hip kinetics as well as kinetics at FKC are computed using ES analysis. Hip power during the swing phase is also evaluated and compared. The results are presented in this paper and discussed. The ES analysis is shown to be a versatile tool to provide insights into the human-mechanism interaction.

About this research paper

What this paper is about

Inverse dynamics analysis of prosthetic legs with polycentric knees is complex due to increased number of links. The present work proposes a simple and general method called equivalent system (ES) analysis. The ES analysis provides forces and moment at hip joint as well as at the functional knee centre (FKC), the instant centre of the polycentric knee. The input to the ES analysis is the motion data. For validation of the proposed method, synthetic motion data for the swing phase of walking with prosthetic legs having different knees are generated by simulations using ADAMS. The hip kinetics evaluated by the proposed method is compared with that from ADAMS. The root mean square errors of the ES analysis are lower than 17 (10 −6 ) N for hip reaction forces and 2.6 (10 −6 ) Nm for the hip moments, thereby validating the proposed method. In order to demonstrate the application of the proposed methodology, the motion data of two transfemoral amputees using single-axis and four-bar knee prostheses are obtained during gait trials. The hip kinetics as well as kinetics at FKC are computed using ES analysis. Hip power during the swing phase is also evaluated and compared. The results are presented in this paper and discussed. The ES analysis is shown to be a versatile tool to provide insights into the human-mechanism interaction.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Inverse dynamics analysis of prosthetic legs with polycentric knees is complex due to increased number of links. The present work proposes a simple and general method called equivalent system (ES) analysis. The ES analysis provides forces and moment at hip joint as well as at the functional knee centre (FKC), the instant centre of the polycentric knee. The input to the ES analysis is the motion data. For validation of the proposed method, synthetic motion data for the swing phase of walking with prosthetic legs having different knees are generated by simulations using ADAMS. The hip kinetics evaluated by the proposed method is compared with that from ADAMS. The root mean square errors of the ES analysis are lower than 17 (10 −6 ) N for hip reaction forces and 2.6 (10 −6 ) Nm for the hip moments, thereby validating the proposed method. In order to demonstrate the application of the proposed methodology, the motion data of two transfemoral amputees using single-axis and four-bar knee prostheses are obtained during gait trials. The hip kinetics as well as kinetics at FKC are computed using ES analysis. Hip power during the swing phase is also evaluated and compared. The results are presented in this paper and discussed. The ES analysis is shown to be a versatile tool to provide insights into the human-mechanism interaction.

Key concepts: Inverse dynamics, Motion analysis, Gait analysis, Swing, Gait, Work (physics), Ground reaction force, Moment (physics)