2023•Proceedings of the ... annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting/Proceedings of a meeting - Precise Time and Time Interval (PTTI) Systems and Applications MeetingRequires access

NIST-F3, a Cesium Fountain Frequency Reference

Gregory W. Hoth, Jeff A. Sherman, A. G. Radnaev, Peter Mitchell, Vladislav P. Gerginov

Open publisher page 6 citations

Abstract

A cesium fountain frequency reference known as NIST-F3 is under development at the National Institute of Standards and Technology (NIST). The fountain is intended to provide input for the NIST timescale and assist with evaluation of NIST’s primary and secondary frequency standards. Here, we describe details of the NIST-F3 apparatus and demonstrate a short-term frequency stability of 2.2 × 10?13/ ? ? for averaging times as long as 5 × 104 s (? is the averaging time in seconds). We also present an initial evaluation of the main frequency biases. Due to the particulars of the microwave cavity design employed in NIST-F3, the fountain exhibits a relatively large tilt sensitivity. We measure fractional frequency shifts of order 10?14/mrad when tilting the fountain. Despite this complication, we show that the tilt sensitivity can be managed with the standard techniques that have been developed for cold-atom fountains. This initial investigation suggests it will be possible to achieve our goal of a fractional frequency stability better than 0.5 × 10?15 for up to a few months of averaging time.

About this research paper

What this paper is about

A cesium fountain frequency reference known as NIST-F3 is under development at the National Institute of Standards and Technology (NIST). The fountain is intended to provide input for the NIST timescale and assist with evaluation of NIST’s primary and secondary frequency standards. Here, we describe details of the NIST-F3 apparatus and demonstrate a short-term frequency stability of 2.2 × 10?13/ ? ? for averaging times as long as 5 × 104 s (? is the averaging time in seconds). We also present an initial evaluation of the main frequency biases. Due to the particulars of the microwave cavity design employed in NIST-F3, the fountain exhibits a relatively large tilt sensitivity. We measure fractional frequency shifts of order 10?14/mrad when tilting the fountain. Despite this complication, we show that the tilt sensitivity can be managed with the standard techniques that have been developed for cold-atom fountains. This initial investigation suggests it will be possible to achieve our goal of a fractional frequency stability better than 0.5 × 10?15 for up to a few months of averaging time.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A cesium fountain frequency reference known as NIST-F3 is under development at the National Institute of Standards and Technology (NIST). The fountain is intended to provide input for the NIST timescale and assist with evaluation of NIST’s primary and secondary frequency standards. Here, we describe details of the NIST-F3 apparatus and demonstrate a short-term frequency stability of 2.2 × 10?13/ ? ? for averaging times as long as 5 × 104 s (? is the averaging time in seconds). We also present an initial evaluation of the main frequency biases. Due to the particulars of the microwave cavity design employed in NIST-F3, the fountain exhibits a relatively large tilt sensitivity. We measure fractional frequency shifts of order 10?14/mrad when tilting the fountain. Despite this complication, we show that the tilt sensitivity can be managed with the standard techniques that have been developed for cold-atom fountains. This initial investigation suggests it will be possible to achieve our goal of a fractional frequency stability better than 0.5 × 10?15 for up to a few months of averaging time.

Key concepts: NIST, Fountain, Frequency standard, Atomic clock, Sensitivity (control systems), Tilt (camera), Computer science, Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
NIST-F3, a Cesium Fountain Frequency Reference — Research Paper | ScholarLens