2023Journal of InstrumentationRequires access

A ceramic-GEM neutron detector with a wide neutron-flux measurement range for the beam monitoring at China spallation neutron source

Lin Zhu, Jianrong Zhou, Li-Xin Zeng, Liang Xiao, Xiaojuan Zhou, Jinhao Tan, Yuanguang Xia, Hong Xu, X. S. Jiang, Wenqin Yang, Yanfeng Wang, Gui-An Yang, Y. G. Xie, H. Teng, Jiajie Li, Yong-Xiang Qiu, P. X. Shen, Songlin Wang, J. Zhuang, Yu-bin Zhao, Junrong Zhang, Zhijia Sun, Yuanbo Chen

Open publisher page 6 citations

Abstract

Abstract The increase of neutron flux in pulsed spallation neutron facilities imposes demands on the neutron detector for beam monitoring, including excellent neutron/gamma discrimination, wide dynamic neutron-flux measurement range, wavelength resolution, and long-term stability. In this paper, we developed a ceramic GEM-based (gas electron multiplier) neutron detector with an active area of 100 mm × 100 mm. It adopted a thinner conversion material and the stopping layer to lower the detection efficiency so as to extend the dynamic measurement range of the detector. The detection efficiency of this detector was investigated by the Monte Carlo (MC) tool FLUKA, showing that the low efficiency around 0.01% for 1 Åneutrons was reached by using a 0.1 μm natB4C converter appended with an aluminum film of 2 μm thickness. Its validation of the wavelength spectra measurement was verified by comparisons with that made with an LND monitor, and it could work at the condition of 7.1 × 109 n/s for 2.5 Åneutrons. In addition, it was demonstrated that this detector was able to measure the beam profile with a position resolution of better than 2.1 ± 0.1 mm. The results of simulations and experiments show that this ceramic-GEM neutron detector can meet the requirements of the direct measurement of high-flux beam, and it will be a new neutron detector for the beam monitoring at the China spallation neutron source (CSNS).

About this research paper

What this paper is about

Abstract The increase of neutron flux in pulsed spallation neutron facilities imposes demands on the neutron detector for beam monitoring, including excellent neutron/gamma discrimination, wide dynamic neutron-flux measurement range, wavelength resolution, and long-term stability. In this paper, we developed a ceramic GEM-based (gas electron multiplier) neutron detector with an active area of 100 mm × 100 mm. It adopted a thinner conversion material and the stopping layer to lower the detection efficiency so as to extend the dynamic measurement range of the detector. The detection efficiency of this detector was investigated by the Monte Carlo (MC) tool FLUKA, showing that the low efficiency around 0.01% for 1 Åneutrons was reached by using a 0.1 μm natB4C converter appended with an aluminum film of 2 μm thickness. Its validation of the wavelength spectra measurement was verified by comparisons with that made with an LND monitor, and it could work at the condition of 7.1 × 109 n/s for 2.5 Åneutrons. In addition, it was demonstrated that this detector was able to measure the beam profile with a position resolution of better than 2.1 ± 0.1 mm. The results of simulations and experiments show that this ceramic-GEM neutron detector can meet the requirements of the direct measurement of high-flux beam, and it will be a new neutron detector for the beam monitoring at the China spallation neutron source (CSNS).

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract The increase of neutron flux in pulsed spallation neutron facilities imposes demands on the neutron detector for beam monitoring, including excellent neutron/gamma discrimination, wide dynamic neutron-flux measurement range, wavelength resolution, and long-term stability. In this paper, we developed a ceramic GEM-based (gas electron multiplier) neutron detector with an active area of 100 mm × 100 mm. It adopted a thinner conversion material and the stopping layer to lower the detection efficiency so as to extend the dynamic measurement range of the detector. The detection efficiency of this detector was investigated by the Monte Carlo (MC) tool FLUKA, showing that the low efficiency around 0.01% for 1 Åneutrons was reached by using a 0.1 μm natB4C converter appended with an aluminum film of 2 μm thickness. Its validation of the wavelength spectra measurement was verified by comparisons with that made with an LND monitor, and it could work at the condition of 7.1 × 109 n/s for 2.5 Åneutrons. In addition, it was demonstrated that this detector was able to measure the beam profile with a position resolution of better than 2.1 ± 0.1 mm. The results of simulations and experiments show that this ceramic-GEM neutron detector can meet the requirements of the direct measurement of high-flux beam, and it will be a new neutron detector for the beam monitoring at the China spallation neutron source (CSNS).

Key concepts: Neutron detection, Spallation Neutron Source, Neutron flux, Spallation, Neutron, Neutron source, Detector, Bonner sphere

Related papers

Back to paper searchBrowse research topicsOriginal source
A ceramic-GEM neutron detector with a wide neutron-flux measurement range for the beam monitoring at China spallation neutron source — Research Paper | ScholarLens