2023•Engineering ReportsOpen access

Reliability analysis of computed tomography equipment using the q‐Weibull distribution

Litian Fan, Zhi Hu, Qingqing Ling, Hanwei Li, Hongliang Qi, Hongwen Chen

Open full text 9 citations

Abstract

Abstract Inspired by the successful application of the q‐Weibull distribution in other research fields, we took the lead to use it in the field of medical devices in this work. The parameter estimation of the q‐Weibull distribution was performed using the probability plot method. The CT failure data from Nanfang Hospital in Guangzhou, China, were used to study the reliability of CT equipment at two levels: the CT system and its seven main components. In terms of evaluation accuracy, the mean squared error, Akaike's information criterion, and the determination coefficient were used to compare the accuracy of fitting of different distribution models. The results show that the accuracy of fitting the q‐Weibull distribution is higher than that of the Weibull distribution in terms of determination coefficient and mean squared error. When considering the complexity of the model, the fit accuracy of the Weibull distribution is better. The results were analyzed using reliability and failure rate plots. The q‐Weibull distribution gives a good fit for the failure data of the CT system and components. Though the Weibull distribution fits better in a few cases, the q‐Weibull distribution can describe the entire “bathtub curve” with only a set of parameters. The findings of this study can be extended to other medical devices.

Open-access reader

About this research paper

What this paper is about

Abstract Inspired by the successful application of the q‐Weibull distribution in other research fields, we took the lead to use it in the field of medical devices in this work. The parameter estimation of the q‐Weibull distribution was performed using the probability plot method. The CT failure data from Nanfang Hospital in Guangzhou, China, were used to study the reliability of CT equipment at two levels: the CT system and its seven main components. In terms of evaluation accuracy, the mean squared error, Akaike's information criterion, and the determination coefficient were used to compare the accuracy of fitting of different distribution models. The results show that the accuracy of fitting the q‐Weibull distribution is higher than that of the Weibull distribution in terms of determination coefficient and mean squared error. When considering the complexity of the model, the fit accuracy of the Weibull distribution is better. The results were analyzed using reliability and failure rate plots. The q‐Weibull distribution gives a good fit for the failure data of the CT system and components. Though the Weibull distribution fits better in a few cases, the q‐Weibull distribution can describe the entire “bathtub curve” with only a set of parameters. The findings of this study can be extended to other medical devices.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Inspired by the successful application of the q‐Weibull distribution in other research fields, we took the lead to use it in the field of medical devices in this work. The parameter estimation of the q‐Weibull distribution was performed using the probability plot method. The CT failure data from Nanfang Hospital in Guangzhou, China, were used to study the reliability of CT equipment at two levels: the CT system and its seven main components. In terms of evaluation accuracy, the mean squared error, Akaike's information criterion, and the determination coefficient were used to compare the accuracy of fitting of different distribution models. The results show that the accuracy of fitting the q‐Weibull distribution is higher than that of the Weibull distribution in terms of determination coefficient and mean squared error. When considering the complexity of the model, the fit accuracy of the Weibull distribution is better. The results were analyzed using reliability and failure rate plots. The q‐Weibull distribution gives a good fit for the failure data of the CT system and components. Though the Weibull distribution fits better in a few cases, the q‐Weibull distribution can describe the entire “bathtub curve” with only a set of parameters. The findings of this study can be extended to other medical devices.

Key concepts: Weibull distribution, Weibull modulus, Reliability (semiconductor), Distribution fitting, Akaike information criterion, Statistics, Failure rate, Mathematics

Related papers

Back to paper searchBrowse research topicsOriginal source
Reliability analysis of computed tomography equipment using the q‐Weibull distribution — Research Paper | ScholarLens