2023•Radiation Physics and ChemistryOpen access

Design and performance study of a proportional counter for low-energy X-rays

Meng Yu Li, Rui Jie Zhao, Tao Xiong, Jin Jie Wu, Lin Fu, Tao Yu, Wei Feng Zhu, Xian Qiang Tang, Ping Zhou Lu, Bing Bing Qu

Open full text 1 citations

Abstract

A cylindrical proportional counter based on a noble gas was designed to accurately measure low-energy X-ray radiation. The detection capability of the proportional counter with different gases and geometries was calculated through the Monte Carlo method . The optimal filling gas and applicable pipe diameter were determined according to the results of the Monte Carlo simulation . Then, energy calibration was performed at the monoenergetic X-ray radiation facility (MXRF) based on Bragg diffraction, and the energy calibration results were verified using the radionuclides 241 Am and 129 I. The relative deviation of the theoretical and measured values of the energy does not exceed 1.4%, and the energy resolution of the designed proportional counter is approximately 10%. It was proved that the linearity of the channel and energy of the proportional counter can be used for energy spectrum analysis, and the proportional counter has a good radionuclide recognition capability. Finally, the detection efficiency of the designed proportional counter was simulated and verified at multiple energy points. A detection efficiency calculation model was established through MCNP5, and the detection efficiency of the proportional counter was measured at the MXRF. The results of the experiment and simulation showed that the proportional counter could reach a highest detection efficiency of 92% in the low-energy region. The average deviation between the experiment and simulation was 1.63% at 10–34 keV and 3.90% at 34–75 keV. The proportional counter can be used for measurement and application of X-rays in the low-energy region.

About this research paper

What this paper is about

A cylindrical proportional counter based on a noble gas was designed to accurately measure low-energy X-ray radiation. The detection capability of the proportional counter with different gases and geometries was calculated through the Monte Carlo method . The optimal filling gas and applicable pipe diameter were determined according to the results of the Monte Carlo simulation . Then, energy calibration was performed at the monoenergetic X-ray radiation facility (MXRF) based on Bragg diffraction, and the energy calibration results were verified using the radionuclides 241 Am and 129 I. The relative deviation of the theoretical and measured values of the energy does not exceed 1.4%, and the energy resolution of the designed proportional counter is approximately 10%. It was proved that the linearity of the channel and energy of the proportional counter can be used for energy spectrum analysis, and the proportional counter has a good radionuclide recognition capability. Finally, the detection efficiency of the designed proportional counter was simulated and verified at multiple energy points. A detection efficiency calculation model was established through MCNP5, and the detection efficiency of the proportional counter was measured at the MXRF. The results of the experiment and simulation showed that the proportional counter could reach a highest detection efficiency of 92% in the low-energy region. The average deviation between the experiment and simulation was 1.63% at 10–34 keV and 3.90% at 34–75 keV. The proportional counter can be used for measurement and application of X-rays in the low-energy region.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A cylindrical proportional counter based on a noble gas was designed to accurately measure low-energy X-ray radiation. The detection capability of the proportional counter with different gases and geometries was calculated through the Monte Carlo method . The optimal filling gas and applicable pipe diameter were determined according to the results of the Monte Carlo simulation . Then, energy calibration was performed at the monoenergetic X-ray radiation facility (MXRF) based on Bragg diffraction, and the energy calibration results were verified using the radionuclides 241 Am and 129 I. The relative deviation of the theoretical and measured values of the energy does not exceed 1.4%, and the energy resolution of the designed proportional counter is approximately 10%. It was proved that the linearity of the channel and energy of the proportional counter can be used for energy spectrum analysis, and the proportional counter has a good radionuclide recognition capability. Finally, the detection efficiency of the designed proportional counter was simulated and verified at multiple energy points. A detection efficiency calculation model was established through MCNP5, and the detection efficiency of the proportional counter was measured at the MXRF. The results of the experiment and simulation showed that the proportional counter could reach a highest detection efficiency of 92% in the low-energy region. The average deviation between the experiment and simulation was 1.63% at 10–34 keV and 3.90% at 34–75 keV. The proportional counter can be used for measurement and application of X-rays in the low-energy region.

Key concepts: Proportional counter, Monte Carlo method, Calibration, Energy (signal processing), Physics, Linearity, Radiation, Computational physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Design and performance study of a proportional counter for low-energy X-rays — Research Paper | ScholarLens