Investigation of Thermal Adaptation and Development of an Adaptive Model under Various Cooling Temperature Settings for Students’ Activity Rooms in a University Building in Malaysia

Nurul Izzati, Sheikh Ahmad Zaki, Hom Bahadur Rijal, Jorge Alfredo Ardila‐Rey, Aya Hagishima, Nurizzatul Atikha

Open full text 16 citations

Abstract

The use of an air conditioner (AC) becomes essential, particularly in a hot and humid climate, to provide a comfortable environment for human activities. The setpoint is the agreed temperature that the building will meet, and the use of the lowest setpoint temperature to accelerate the cooling of indoor spaces should be avoided. A comprehensive field study was conducted under various cooling temperature settings in two student activity rooms in a university building in Malaysia, so as to understand respondents’ characteristics and behavior toward AC usage, to estimate the comfort at various indoor temperatures, to develop an adaptive model of thermal comfort in AC spaces, and to compare the comfort temperature with related local and international indoor thermal environmental standards. The findings indicated that water intake and clothing insulation affected personal thermal comfort. Moreover, the mean comfort temperature for respondents was 24.3 °C, which is within an indoor thermal comfort zone of 23–27 °C. The findings suggest that the preference of occupants living in a hot and humid region for lower temperatures means that setting temperatures lower than 24 °C might underestimate the indoor comfort temperature. Additionally, an adaptive relationship can be derived to estimate the indoor comfort temperature from the prevailing outdoor temperature.

Open-access reader

About this research paper

What this paper is about

The use of an air conditioner (AC) becomes essential, particularly in a hot and humid climate, to provide a comfortable environment for human activities. The setpoint is the agreed temperature that the building will meet, and the use of the lowest setpoint temperature to accelerate the cooling of indoor spaces should be avoided. A comprehensive field study was conducted under various cooling temperature settings in two student activity rooms in a university building in Malaysia, so as to understand respondents’ characteristics and behavior toward AC usage, to estimate the comfort at various indoor temperatures, to develop an adaptive model of thermal comfort in AC spaces, and to compare the comfort temperature with related local and international indoor thermal environmental standards. The findings indicated that water intake and clothing insulation affected personal thermal comfort. Moreover, the mean comfort temperature for respondents was 24.3 °C, which is within an indoor thermal comfort zone of 23–27 °C. The findings suggest that the preference of occupants living in a hot and humid region for lower temperatures means that setting temperatures lower than 24 °C might underestimate the indoor comfort temperature. Additionally, an adaptive relationship can be derived to estimate the indoor comfort temperature from the prevailing outdoor temperature.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The use of an air conditioner (AC) becomes essential, particularly in a hot and humid climate, to provide a comfortable environment for human activities. The setpoint is the agreed temperature that the building will meet, and the use of the lowest setpoint temperature to accelerate the cooling of indoor spaces should be avoided. A comprehensive field study was conducted under various cooling temperature settings in two student activity rooms in a university building in Malaysia, so as to understand respondents’ characteristics and behavior toward AC usage, to estimate the comfort at various indoor temperatures, to develop an adaptive model of thermal comfort in AC spaces, and to compare the comfort temperature with related local and international indoor thermal environmental standards. The findings indicated that water intake and clothing insulation affected personal thermal comfort. Moreover, the mean comfort temperature for respondents was 24.3 °C, which is within an indoor thermal comfort zone of 23–27 °C. The findings suggest that the preference of occupants living in a hot and humid region for lower temperatures means that setting temperatures lower than 24 °C might underestimate the indoor comfort temperature. Additionally, an adaptive relationship can be derived to estimate the indoor comfort temperature from the prevailing outdoor temperature.

Key concepts: Setpoint, Thermal comfort, Architectural engineering, Environmental science, Operative temperature, Clothing, Mean radiant temperature, Air conditioning

Related papers

Back to paper searchBrowse research topicsOriginal source
Investigation of Thermal Adaptation and Development of an Adaptive Model under Various Cooling Temperature Settings for Students’ Activity Rooms in a University Building in Malaysia — Research Paper | ScholarLens