2022Unpublished venueRequires access

An approach for the measurement of focal lengths of a weak thermally-induced negative lens

Ruina Fang, Weijiang Wang, Yang Jiao, Zhendong Shi, Hao Xing, Yun Huang, Juhong Han, Qing Luo, He Cai, Guofei An, Meng Zhang, Xi Yang, You Wang

Open publisher page 0 citations

Abstract

In this paper, a simple and effective method is proposed for measuring the focal length of a weak negative thermallyinduced lens. Generally, it is very difficult to measure the focal length larger than 1000 mm of a weak thermally-induced lens by utilizing the traditional procedures. In our experiment, we planned to construct a Yb:KGW laser system almost without the thermally-induced lens in which the focal length of the laser crystal should be measured precisely. With respect to the optical features of Yb:KGW crystal, the thermally-induced characteristics look like something of a negative lens with weak effects. The steps of measuring the focal length of a thermally-induced lens of the laser medium have been adopted as follows. First, the relationship between the focal length f1 of a positive assistant lens as well as the position of the assistant lens and the focal length fT of a thermally-induced lens were carefully analyzed and the experimental setup were designed through the theoretical simulation. Secondly, the variation of the spot size and post position for a He-Ne probe laser have been experimentally investigated after the probe laser beam passed through a thermally-induced lens (fT) and an assistant lens (f1) with the different drive currents of a pump LD with the wavelength of 980 nm. Then, the post position for a He-Ne laser beam can be obtained by use of a least square method, and then the focal length of a weak thermally-induced lens can be deduced with an indirect detection method. In this paper, we introduce a new technique for the measurement of the focal length with the absolute value large than 1000 mm of a negative lens, which has not been reported until now. The results might be useful for the evaluation of a weak thermally-induced lens of almost all solid-state lasers (SSLs).

About this research paper

What this paper is about

In this paper, a simple and effective method is proposed for measuring the focal length of a weak negative thermallyinduced lens. Generally, it is very difficult to measure the focal length larger than 1000 mm of a weak thermally-induced lens by utilizing the traditional procedures. In our experiment, we planned to construct a Yb:KGW laser system almost without the thermally-induced lens in which the focal length of the laser crystal should be measured precisely. With respect to the optical features of Yb:KGW crystal, the thermally-induced characteristics look like something of a negative lens with weak effects. The steps of measuring the focal length of a thermally-induced lens of the laser medium have been adopted as follows. First, the relationship between the focal length f1 of a positive assistant lens as well as the position of the assistant lens and the focal length fT of a thermally-induced lens were carefully analyzed and the experimental setup were designed through the theoretical simulation. Secondly, the variation of the spot size and post position for a He-Ne probe laser have been experimentally investigated after the probe laser beam passed through a thermally-induced lens (fT) and an assistant lens (f1) with the different drive currents of a pump LD with the wavelength of 980 nm. Then, the post position for a He-Ne laser beam can be obtained by use of a least square method, and then the focal length of a weak thermally-induced lens can be deduced with an indirect detection method. In this paper, we introduce a new technique for the measurement of the focal length with the absolute value large than 1000 mm of a negative lens, which has not been reported until now. The results might be useful for the evaluation of a weak thermally-induced lens of almost all solid-state lasers (SSLs).

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this paper, a simple and effective method is proposed for measuring the focal length of a weak negative thermallyinduced lens. Generally, it is very difficult to measure the focal length larger than 1000 mm of a weak thermally-induced lens by utilizing the traditional procedures. In our experiment, we planned to construct a Yb:KGW laser system almost without the thermally-induced lens in which the focal length of the laser crystal should be measured precisely. With respect to the optical features of Yb:KGW crystal, the thermally-induced characteristics look like something of a negative lens with weak effects. The steps of measuring the focal length of a thermally-induced lens of the laser medium have been adopted as follows. First, the relationship between the focal length f1 of a positive assistant lens as well as the position of the assistant lens and the focal length fT of a thermally-induced lens were carefully analyzed and the experimental setup were designed through the theoretical simulation. Secondly, the variation of the spot size and post position for a He-Ne probe laser have been experimentally investigated after the probe laser beam passed through a thermally-induced lens (fT) and an assistant lens (f1) with the different drive currents of a pump LD with the wavelength of 980 nm. Then, the post position for a He-Ne laser beam can be obtained by use of a least square method, and then the focal length of a weak thermally-induced lens can be deduced with an indirect detection method. In this paper, we introduce a new technique for the measurement of the focal length with the absolute value large than 1000 mm of a negative lens, which has not been reported until now. The results might be useful for the evaluation of a weak thermally-induced lens of almost all solid-state lasers (SSLs).

Key concepts: Focal length, Lens (geology), Optics, Laser, Focal point, Materials science, Cardinal point, Position (finance)

Related papers

Back to paper searchBrowse research topicsOriginal source
An approach for the measurement of focal lengths of a weak thermally-induced negative lens — Research Paper | ScholarLens