2022•Annals of Thoracic and Cardiovascular SurgeryOpen access

I-Composite Graft with Right Internal Thoracic Artery and Right Gastroepiploic Artery in Coronary Artery Bypass Grafting

Makoto Shirakawa, Masami Ochi, Yôsuke Ishii

Open full text 6 citations

Abstract

PURPOSE: When added to the internal thoracic artery (ITA), the right gastroepiploic artery (GEA) has been used as an in-situ graft or an I-composite right ITA-right GEA graft in coronary artery bypass grafting (CABG). We aimed to verify its potential. METHODS: We evaluated 104 patients who underwent first isolated CABG with this I-composite graft. The number of distal anastomoses, graft flow (GF) and pulsatility index (PI) during surgery, and graft patency in the early term regarding this I-composite graft were evaluated. RESULTS: The number of total distal anastomoses and distal anastomoses with arterial grafts were 4.17 ± 0.81 and 3.63 ± 0.81, respectively. This I-composite graft achieved 2.38 ± 0.69 distal anastomoses. GF tended to increase according to the increased number of distal anastomoses (p = 0.241), and the PI maintained a low score regardless of the number of distal anastomoses (p = 0.834). Graft patency was 95.5%; moreover, the number of distal anastomoses with this I-composite graft did not affect early-term graft patency. CONCLUSION: Right GEA utility was expanded as this I-composite graft in addition to in-situ graft. This I-composite graft has an adequate flow capacity for revascularization in non-left anterior descending coronary artery lesions.

Open-access reader

About this research paper

What this paper is about

PURPOSE: When added to the internal thoracic artery (ITA), the right gastroepiploic artery (GEA) has been used as an in-situ graft or an I-composite right ITA-right GEA graft in coronary artery bypass grafting (CABG). We aimed to verify its potential. METHODS: We evaluated 104 patients who underwent first isolated CABG with this I-composite graft. The number of distal anastomoses, graft flow (GF) and pulsatility index (PI) during surgery, and graft patency in the early term regarding this I-composite graft were evaluated. RESULTS: The number of total distal anastomoses and distal anastomoses with arterial grafts were 4.17 ± 0.81 and 3.63 ± 0.81, respectively. This I-composite graft achieved 2.38 ± 0.69 distal anastomoses. GF tended to increase according to the increased number of distal anastomoses (p = 0.241), and the PI maintained a low score regardless of the number of distal anastomoses (p = 0.834). Graft patency was 95.5%; moreover, the number of distal anastomoses with this I-composite graft did not affect early-term graft patency. CONCLUSION: Right GEA utility was expanded as this I-composite graft in addition to in-situ graft. This I-composite graft has an adequate flow capacity for revascularization in non-left anterior descending coronary artery lesions.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: When added to the internal thoracic artery (ITA), the right gastroepiploic artery (GEA) has been used as an in-situ graft or an I-composite right ITA-right GEA graft in coronary artery bypass grafting (CABG). We aimed to verify its potential. METHODS: We evaluated 104 patients who underwent first isolated CABG with this I-composite graft. The number of distal anastomoses, graft flow (GF) and pulsatility index (PI) during surgery, and graft patency in the early term regarding this I-composite graft were evaluated. RESULTS: The number of total distal anastomoses and distal anastomoses with arterial grafts were 4.17 ± 0.81 and 3.63 ± 0.81, respectively. This I-composite graft achieved 2.38 ± 0.69 distal anastomoses. GF tended to increase according to the increased number of distal anastomoses (p = 0.241), and the PI maintained a low score regardless of the number of distal anastomoses (p = 0.834). Graft patency was 95.5%; moreover, the number of distal anastomoses with this I-composite graft did not affect early-term graft patency. CONCLUSION: Right GEA utility was expanded as this I-composite graft in addition to in-situ graft. This I-composite graft has an adequate flow capacity for revascularization in non-left anterior descending coronary artery lesions.

Key concepts: Right gastroepiploic artery, Medicine, Gastroepiploic Artery, Internal thoracic artery, Bypass grafting, Artery, Cardiology, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
I-Composite Graft with Right Internal Thoracic Artery and Right Gastroepiploic Artery in Coronary Artery Bypass Grafting — Research Paper | ScholarLens