2022Optics ExpressOpen access

Tunable doublets: piezoelectric glass membrane lenses with an achromatic and spherical aberration control

Hitesh Gowda Bettaswamy Gowda, Matthias C. Wapler, Ulrike Wallrabe

Open full text 9 citations

Abstract

We present two versions of tunable achromatic doublets based on each two piezoelectrically actuated glass membranes that create the surface of fluid volumes with different dispersions: a straightforward back-to-back and a more intricate stack of the fluid volumes. In both cases, we can control the chromatic focal shift and focal power independently by a suitable combination of actuation voltages on both active membranes. The doublets have a large aperture of 12 mm at an outer diameter of the actuator of 18 mm, an overall thickness of 3 mm and a short response time of around 0.5 ms and, in addition, provide spherical aberration correction. The two designs have an achromatic focal power range of ±2.2 m −1 and ±3.2 m −1 or, for the purpose of actively correcting chromatic errors, a chromatic focal shift at vanishing combined focal power of up to ±0.08 m −1 and ±0.12 m −1 .

About this research paper

What this paper is about

We present two versions of tunable achromatic doublets based on each two piezoelectrically actuated glass membranes that create the surface of fluid volumes with different dispersions: a straightforward back-to-back and a more intricate stack of the fluid volumes. In both cases, we can control the chromatic focal shift and focal power independently by a suitable combination of actuation voltages on both active membranes. The doublets have a large aperture of 12 mm at an outer diameter of the actuator of 18 mm, an overall thickness of 3 mm and a short response time of around 0.5 ms and, in addition, provide spherical aberration correction. The two designs have an achromatic focal power range of ±2.2 m −1 and ±3.2 m −1 or, for the purpose of actively correcting chromatic errors, a chromatic focal shift at vanishing combined focal power of up to ±0.08 m −1 and ±0.12 m −1 .

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We present two versions of tunable achromatic doublets based on each two piezoelectrically actuated glass membranes that create the surface of fluid volumes with different dispersions: a straightforward back-to-back and a more intricate stack of the fluid volumes. In both cases, we can control the chromatic focal shift and focal power independently by a suitable combination of actuation voltages on both active membranes. The doublets have a large aperture of 12 mm at an outer diameter of the actuator of 18 mm, an overall thickness of 3 mm and a short response time of around 0.5 ms and, in addition, provide spherical aberration correction. The two designs have an achromatic focal power range of ±2.2 m −1 and ±3.2 m −1 or, for the purpose of actively correcting chromatic errors, a chromatic focal shift at vanishing combined focal power of up to ±0.08 m −1 and ±0.12 m −1 .

Key concepts: Achromatic lens, Optics, Focal length, Chromatic aberration, Materials science, Chromatic scale, Spherical aberration, Aperture (computer memory)

Related papers

Back to paper searchBrowse research topicsOriginal source
Tunable doublets: piezoelectric glass membrane lenses with an achromatic and spherical aberration control — Research Paper | ScholarLens